MIG/MAG ROBO welding torch
8 Putting out of operation
NOTICE
• When decommissioning the system, ensure that the procedures for switching off the
welding components are observed.
1 Wait until the shielding gas post-flow time has expired.
2 Close the shut-off valve for the gas supply.
3 Switch off the power source.
9 Maintenance and cleaning
Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free
operation.
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to for the entire duration of maintenance,
servicing, mounting, dismounting and repair work:
• Switch off the power source.
• Close off the compressed air supply.
• Close off the gas supply.
• Close off the coolant supply.
• Disconnect the coolant supply and return hoses.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
DANGER
Verbrennungsgefahr
Verbrennungsgefahr durch austretendes heißes Kühlmittel und heiße Oberflächen.
• Schalten Sie das Umlaufkühlgerät vor Beginn der Wartungs-, Instandhaltungs-, Montage-
bzw. Demontage- und Reparaturarbeiten aus.
• Lassen Sie die Schweißbrenner abkühlen.
• Tragen Sie entsprechende Schutzhandschuhe
BAL.0046 • 2019-02-07
8 Putting out of operation
EN - 13