5.4
HOT WATER
ECONOMISER
ADJUSTMENT
All
models can be equipped with a warm
water mixer which permits to adjust the water outlet
temperature and to optimize system performance.
To adjust the hot water economiser, it is necessary
to remove the top panel of the machine, proceeding
as follows:
unscrew the central screw in the upper panel
(Fig. 22);
to adjust the temperature of the hot water deliv-
ered from the nozzle, turn the register knob
CLOCKWISE / ANTICLOCKWISE to INCREASE
/ REDUCE the temperature;
at the end of this operation, refit the top panel on
the machine.