Descargar Imprimir esta página

Lighting Instructions - Char-Griller Flavor Pro Manual Del Proprietário

Publicidad

Idiomas disponibles

Idiomas disponibles

Leak Test
1. In a spray bottle mix 6-9ml. solution, 1 part dish washing soap, 3 parts water.
2. Ensure control valves/burner knobs are in the off position and that regulator is securely connected.
3. Open LP cylinder valve completely by turning wheel counterclockwise.
4. Apply the solution to the hose, gas valve, and regulator, and cylinder.
5. If bubbles form and grow on any of the tested components, there is a leak in the component. No
bubbles means no leak.
6. If a leak has been identified please retest starting with steps 2-5. If leak persists, call customer
service, 912-638-4724 or consult your owner's manual for how to replace or repair grill components.

Lighting Instructions

Always open hood while igniting grill. If grill does not light, always wait 5 minutes for gas to clear before
relighting. Failure to do either may result in an explosive flare-up, which can cause serious bodily
injury or death. Once lit, but before cooking on grill for first time, let grill sit for 15 minutes with hood
closed. This heat cleans grill's internal parts from anything they may have come into contact with during
manufacturing and shipping.
Main Burners
Make sure there are no obstructions of airflow to gas unit. Spiders and
insects can nest within and clog the burner tube. A clogged burner tube can
lead to a fire beneath appliance.
1. Make sure all burner knobs are in OFF position and the grill hood is open.
2. Open valve on LP gas cylinder.
3. To ignite a burner, push in and rotate knob counterclockwise to "HI," then push and hold Electronic
Ignition Button until burner lights. If burner does not light in 5 seconds, turn burner OFF, wait 5
minutes for gas to clear and repeat procedure.
Repeat for all desired burners. Light only burners intended for use.
4. Adjust knobs to desired cooking setting.
After lighting, observe burner flame and make sure all burner ports are lit.
If burner flame goes out during operation, immediately turn gas off on control panel and gas cylinder
valve. Open hood and let gas clear for 5 minutes before relighting. Clean grill after each use. DO NOT
use abrasive or flammable cleaners, as they damage parts and may start a fire.
Shutting Off Burners
1. Turn knob(s) clockwise to HI position, then push in and turn to OFF. Never force knob without
pushing in, as this can damage valve and knob.
2. Promptly close gas cylinder valve.
3. Close grill hood.
C-3