The weighing indicator can be operated from the battery if desired. The battery life is approsimately 50
hours.
When the battery needs charging a symbol on the weight display will turn on. The battery should be char-
ged when the symbol is on. The scale will still operate for about 10 hours after which it will automatically
switch off to protect the battery.
To charge the battery simply plug into the mains power. The scale does not need to be turned on.
The battery should be charged for 12 hours for full capacity.
Just under the quantity display is an LED to indicate the status of battery charging. When the scale is plu-
gged into the mains power the internal battery will be charged. If the LED is green the battery has a full
charge. If it is Red the battery is nearly discharged and yellow indicates the battery is being charged.
As the battery is used it may fail to hold a full charge. If the battery life becomes unacceptable then contact
your distributor.
The BR30 can be ordered with an optional RS232 output.

9.1. BASIC INFORMATION

Specifications:
RS232 output of weighing data.
ASCII code.
7/8 data bits.
Parity setable.
Baud rate from 600bps to 9600bps.
9.2. NORMAL OUTPUT
Data format for normal weighing operations, parts counting or recalling of totals from memory will all be
different.
Examples follow:
Normal output
S/N
The number increments every time a new value is stored in memory.
GW
GW for gross weight, NT for net weight and a unit of weight
<If>
Includes 2 line feeds.
<If>
When recalling the total weight stored in the accumulation memory the output format is:
****************
<If>
Total No:
Total wt:
****************
9.3. CONTINUOUSLY OUTPUT PROTOCOL
con1: weighing mode
,
|
1
|
Header
nator
|
Header1: ST=STABLE, US=UNSTABLE
Header2: NT=NET, GS=GROSS
28
A line of stars is shown.
Includes 1 line feed.
3
Times of the accumulation memory.
0.447kg
Weight of the accumulation memory.
- /
2
|
Header
USER'S MANUAL

8. BATTERY OPERATION

Connector: 25 pin d-subminiature socket.
Pin 2: Input.
Pin 3: Output.
Pin 5: Signal Ground.
Weight data
BR20 | BR30
EN
9. RS232 OUTPUT
k
g
CR
LF
| |
| | termi-
Weight unit