F4 - Factory reset
Button
Description
Start the selection menu (only if there is no water flowing)
- Select by pressing and holding the - / + buttons simultaneously.
- Select F4 by turning the ring.
• Start F4 - Factory reset
=> Confirm selection by simultaneously pressing the - / + buttons.
- Press the buttons + of the digital controller.
- Press the buttons - of the digital controller.
- Press the buttons Start/Stop of the digital controller.
=> Confirm selection by simultaneously pressing the - / + buttons.
Abort the menu by pressing and holding the Start/Stop button or
after 3 minutes whithout triggering.
Misentry, start again F4.
F5 - Configure digital diverter buttons-not for 36 294/36 351
Button
Description
Start the selection menu (only if there is no water flowing)
- Select by pressing and holding the - / + buttons simultaneously:
- Select F5 by turning the ring:
• Start F5 - Configure digital diverter buttons
=> Confirm selection by simultaneously pressing the - / + buttons.
- Press one of the diverter buttons 1, 2 or 3.
- Change point of discharge by turning the digital controler ring.
The buttons are assigned to the points of discharge 1 - 2 - 3.
After that comes 0 (point of discharge closed), maximal two points
of discharge could be set to 0.
- Press next diverter button.
- Pressing the - / + buttons simultaneously saves the selection and
exits the menu.
Abort the menu by pressing and holding the Start/Stop button or
after 3 minutes whithout triggering.
Activating continuous operation
With the transceiver, the functional unit can be set to
continuous operation for the purposes of flushing or to perform
a thermal desinfection:
1. The functional unit is off, there is no water flowing and the
digital controller is not in pause mode (wait 30 seconds if
required).
2. Disconnect and reconnect the transceiver's plug-in
connector (C), see fold-out page II, Fig. [8].
3. Wait until the indicator lamp (C2) flashes blue, green
and red, then press the button (C1) within 1 minute.
The indicator lamp flashes blue three times.
4. The functional unit is now open for 15 minutes. After
the 15 minutes have elapsed, the indicator lamp (C2)
flashes blue three times.
Caution: Risk of scalding.
Do not stay in the wet area.
Cancel by pressing the button (C1) or any button on the digital
controller/diverter, the indicator lamp (C2) flashes blue three
times.
English
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 4x.
Illuminated ring flashes green 1x.
Illuminated segment flashes blue 1x.
Illuminated segment flashes blue 1x.
Illuminated segment flashes blue 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
Illuminated ring flashes violet 3x.
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 5x.
Illuminated ring flashes green 1x.
The water flow starts and segment of
selected button flashes blue 1x.
The water flow changes to the selected
point of discharge.
The water flow starts and segment of
selected button flashes blue 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
Maintenance
Inspect and clean all components and replace if necessary.
Close isolation valve.
Disconnect voltage supply.
Disconnect all plug-in connectors, see fold-out page II,
Fig. [7] and [8].
I. Change digital controller/diverter batteries, see fold-out
page III, Fig. [12].
Batteries which are almost discharged are indicated by
shortened signals of the illuminated ring after pressing a
button. Batteries must be changed at the latest when signals
are no longer detected.
Lever off base and change all batteries, see Technical
product information for the digital controller/diverter.
Insert batteries with correct polarity.
Assemble in reverse order.
4