Flush the functional unit, see fold-out page II, Figs. [9]
and [10].
1. Remove screw plug (D), see fold-out page II, Fig. [9].
2. Remove the non-return valve (E) and the filter (F).
3. Install the flushing plugs (G) in the non-return valve seat
recesses, see Fig. [10].
4. Open the cold and hot water supply.
Flush pipes thoroughly before and after installation.
5. Close the cold and hot water supply and remove the flushing
plugs (G), see Fig. [10].
6. Install the filter (F) and the non-return valve (E), see Fig. [9].
7. Install the screw plug (D).
Open the hot and cold water supply and check
connections for leakage.
Final installation
Insert batteries into digital controller/diverter, see
Technical product information for the digital controller/diverter.
Insert batteries with correct polarity.
The digital controller/diverter is registered with the functional
unit in the plant.
Operation of the digital controller, see fold-out page III, Fig. [11].
Button
Description
Start/Stop button
Starts and stops the water flow at the saved water temperature and
flow rate.
Pause button
Interrupts the flow of water. The flow is resumed with the last selected
settings by pressing the button again within 30 seconds.
Temperature buttons
Start the water flow and decrease or increase the water temperature.
Display when maximum temperature is reached.
Display when minimum temperature is reached.
Set flow rate
Turning clockwise starts the functional unit and increases the flow
rate.
Turning anti-clockwise reduces the flow rate.
Memory function
The current temperature and flow rate can be saved when the water
is running by pressing and holding the button.
Warm-up mode
If no water is flowing and the faucet is not in Pause mode, pressing
and holding the button activates warm-up mode. When the preset
temperature is reached, the water flow is stopped (complete after 2
minutes). The water flow is started by pressing the button again.
Cleaning service mode
With no water flow, simultaneously press and hold both buttons to
activate the cleaning service mode.
Once activated the spout and shower controls are locked and without
function for 2 minutes.
To end the cleaning service mode before the 2 minutes has ended,
simultaneously press and hold both buttons.
English
Secure digital controller/diverter, see Technical product
information for the digital controller/diverter.
Establish voltage supply via plug-in power supply
unit 65 912 or control cabinet power supply unit 36 078
(not included in the scope of delivery), see fold-out page I.
The indicator lamp (C2) of the transceiver (C) then flashes
blue, green and red, see Fig. [8].
The buttons of the digital controller/diverter are now
inoperative for 3 minutes.
Fit lid and fasten with screw (H), see Fig. [4].
Start waterflow and check temperature, see Fig. [11], fold out
page III.
The functional unit must be adapted to the local conditions,
see section Digital controller selection menu, F2 -
Calibration.
Settings in the event of a power failure/when changing
batteries
No settings saved by the user will be lost when changing the
batteries or in the event of an interruption of the power supply
to the functional unit.
Visualization
The temperature is represented by
the illuminated ring.
The temperature is represented by
the illuminated ring.
Illuminated ring flashes red 3x.
Illuminated ring flashes blue 3x.
Modification of flow rate.
Illuminated ring flashes green 3x and
water flow is interrupted briefly.
Illuminated ring flashes blue 3x at the start
and end of the warm-up phase.
Illuminated ring flashes violet 3x.
Illuminated ring flashes violet 1x when
actuated.
Illuminated ring flashes violet 3x.
2