Connection To The Water Supply; Connection To The Water Drain; Conversion To A Different Type Of Gas; Replacing The Open Fire Burner Nozzles - ALI 90GL/G400 Instrucciones Para Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41
Connect the conductor to the terminal with the symbol
the outside part of the bottom.
8.4

CONNECTION TO THE WATER SUPPLY

The appliance must be connected to a potable water supply.
The water inlet pressure must be between 150 kPa and 300
kPa. Use a pressure reducer if the inlet pressure is above the
maximum permitted level.
Install a mechanical filter and a shut-off valve upstream of
the appliance in an easily accessible point.
Make sure the water circuit is free of ferrous particles
before connecting the filter and the appliance.
Seal any unused connectors with a plug.
Once the appliance has been installed, check for gas leaks
at the connection points.
8.5

CONNECTION TO THE WATER DRAIN

The water drainage system must be made using materials
resistant to temperatures of 100 °C.
The bottom of the appliance must not be subjected to steam
produced by drainage of hot water. Install a siphoned floor
drain with grating below the water drain cock of Boiling pans
and in front of Bratt pans.
9

CONVERSION TO A DIFFERENT TYPE OF GAS

Table T1 specifies, for each country:
which gas can be used for the appliance.
The nozzles and settings for each gas that can be used.
For nozzles, the number indicated in table T1 is also
stamped on the body of nozzles.
To convert the appliance to the local gas type, follow the
instructions given in T1 and carry out the steps below :
Replace the main burner nozzle (UM).
Adjust the main burner's air regulator to distance A.
Replace the pilot burner nozzle (UP).
Adjust the pilot burner air flow (if necessary).
Replace the gas valve minimum nozzle (Um).
Affix the adhesive tab indicating the new type of gas used.
The nozzles and adhesive tabs are supplied with the
appliance.

9.1 REPLACING THE OPEN FIRE BURNER NOZZLES

Remove the control panel.
• Loosen the fixing screw of the air sleeve (V).
• Unscrew the nozzle UM and install the appropriate nozze
indicated in table T1.
• Adjust the primary air distance (A) accordino to the values
listed in Table 1.
9.2

REPLACING THE MINIMUM SCREW

Remove the control panel.
Remove nozzle UM and replace it with the one indicated in
table T1.
• Retighten nozzle UM.
Re-assemble all parts. For assembly, proceed in reverse
order.

9.3 REPLACING THE PILOT NOZZLE

Remove the control panel.
• Remove nozzle UM and replace it with the one indicated in
table T1.
• Retighten nozzle UM.
• Slacken screw V and position the air regulator at distance
A as indicated in table T1.
• Retighten screw V fully.
on
• Re-assemble all parts.For assembly, proceed in reverse
order.

10 COMMISSIONING

See Chapter "INSTRUCTIONS FOR MAINTENANCE".

INSTRUCTIONS FOR USE

REMINDERS FOR THE USER
The manufacturer will not be liable for any damage or
injury resulting from failure to observe the following
rules.
Read
this
manual
information for safe installation, use and maintenance of
the appliance.
Keep this manual in a safe place known to all users so that
it can be consulted throughout the working life of the
appliance.
Installation, conversion to a different type of gas and
appliance maintenance must be carried out by qualified
technicians authorized by the manufacturer, in compliance
with current safety standards and the instructions in this
manual.
For after-sales service, contact technical assistance
centres authorized by the manufacturer and demand the
use of original spare parts.
Have the appliance serviced at least twice a year. The
manufacturer recommends taking out a service contract.
The appliance is designed for professional use and must
be operated by trained personnel.
The appliance is to be used for cooking food as specified in
the prescriptions for use. Any other use is considered to be
improper.
Do not allow the appliance to operate empty for prolonged
periods.
Only pre-heat the oven just before use.
Do not leave the appliance unattended while in operation.
In the event of an appliance fault or malfunction, shut the
gas shut-off valve and/or switch the appliance off at the
main switch installed up line.
Clean the appliance following the instructions given in
Chapter "INSTRUCTIONS FOR CLEANING".
Do not store flammable materials in close proximity to the
appliance. FIRE HAZARD.
Do not obstruct any air vents or drains present on the
appliance.
Do not tamper with appliance components.
Do not pour water in the container when it is empty and
hot, as the burners may go out.
• Children should be supervised to ensure that they do not
play with the appliance.
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their
safety.

USING THE GAS LAVA STONE GRILL

11
REMINDERS FOR USE
• The appliance is designed for cooking foods directly on the
grille ( steaks, hamburgers, fish, vegetables, etc.).
carefully.
It
provides
important
31

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido