6600
INSTALLATION OF TYPE 6611/AU WITH BRACKETS TYPE R660
- Install the interphone away from sources of light and heat
- Make a 120x120mm (nearly) hole in the plasterboard wall at 1,40 m. high
from the floor to the lower border.
- Fix the bracket to the intephone as indicated in figure, keeping the cursors
well aligned to the intephone sides.
- Connect the terminal block.
- Insert the intephone inside the wall in plasterboard.
- Tighten the screws so as the cursors can get closer to the plasterboard
wall.
- By screwing, the cursors should get aligned orthogonally to the inte-
phone.
- Insert the side grids, paying attention that the one with the slot for the
microphone must be inserted on the right.
Part. 1
INSTALLATION OF TYPE 6711/AU
- Install the interphone away from sources of light and heat.
- Fix the intephone fixing plate at 1,40m. from the ground level to the lower
border.
- Connect the terminal block.
- Insert the intephone according to the 1 and 2 arrow direction
- To remove the intephone from the plate hook, operate with a screw dri-
ver on the security lock (placed on the upper side and behind the moni-
tor), and remove it according to the 3 and 4 arrow direction.
Surface wall-mounting version
Fig. 2A
INSTALLATION OF TYPE 661C/AU
- Fix the stub of the surface wall-mounted interphone and hook the inter-
phone to the stub.
- Connect the terminal block.
Table version
139
mm
141mm
Fig. 2B
139
mm
141mm
125mm
Fig. 2C
40mm
125
mm
7