Technical Data
F
2
T_F
min
[Hz]
[s]
Default
57.00
0.16
Range
56.5-57.5
0.1-3.0
Table 5.4 Default Frequency Trip Levels and Trip Times
NOTICE
The values apply only to IEEE 1547.
5.3 Conformity
International standards
Directive LVD
Directive EMC
Safety
Functional safety
EMC, immunity
EMC, emission
Utility interference
CE
Utility characteristics
Table 5.5 International Standards Compliance
Approvals and certificates are available from the download
area at www.sma.de.
2
F
1
T_F
min
min
min
[Hz]
[s]
59.30
10.00
57.0-59.8
0.16-300
L00410644-01_2q / Rev. date: 2014-06-02
1
F
1
T_F
max
max
[Hz]
[s]
60.50
0.16
60.1-60.9
0.16-3.0
MLX series
2006/95/EC
2004/108/EC
IEC 62109-1/IEC 62109-2
UL 1741
UL 508i
IEC 62109-2
UL 1741/IEEE 1547
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
CISPR 11 Class B
FCC Part 15
EN 61000-3-12
IEC 61727
EN 50160
IEEE 1547 UI
1
F
2
T_F
2
max
max
[Hz]
[s]
-
-
60.1-61.0
0.1-3.0
Yes
5
5
33