Accessories for electrical actuators
Heating element

6.2 Function

The heating element is mounted on the base board and is connected electrically via a
flat cable (X1). The temperature is measured with a temperature sensor, which is
mounted on this element. Between 0–5 °C, the heating element is switched on.

6.3 Assembly

 Disconnect the actuator from the supply voltage.
 Remove the housing cover.
 Take the board out of its packaging and check for damages.
 Screw three spacer bolts 1 into installation domes and tighten by hand.
 Fasten board 3 to the spacer bolts with screws 2 and washers.
 Plug the flat cable into the plug X1 4.
 Close the housing cover.
 Connect the supply voltage.