Middle position
15.6 Setting the middle position
Move the actuator to the desired middle position. Activation via terminal 1 and
terminal 2.
Turn switching cam 3 clockwise to the switching point of switch S3.
Turn switching cam 4 counterclockwise to the switching point of switch S4.
S3 and S4 are activated, the two cams point in opposite directions.
If necessary, readjust cams 3 and 4 until the desired middle position is reached
(see position of the ball).
Close the actuator with the housing cover.
The middle position is now set.