Mechanical Attachment

Preparation
Mounting
DOK-MOTOR*-IDYN*A*ATEX-IB02-D5-P
Before installing the motor, check whether the required information is
present on the designation label of the motor, such as the
• device group and device category,
• explosion subgroup,
• maximum permitted surface temperature,
correspond to the local permitted conditions for use in hazardous areas.
Check the components for visible damage. Defective components may
not be mounted.
Before installation, ensure that the environmental conditions at the
location of use, such as the ambient temperature, the humidity, the
vibration, and shock stresses do not exceed the information in the project
planning manual of the motor.
IndraDyn A motors are manufactured either for flange assembly (design
05) or for foot assembly (design 35). You can find details regarding the
fastening holes in the motor dimension sheet in the project planning
manual. For fastening, the following general assignment applies:
(1):
Holes for flange assembly
(2):
Assembly feet (on both sides) for foot assembly
Fig. 5-4:
Motor mounting holes
B05 (flange assembly)
Hole
Ø [mm]
MAD/MAF
100
14
130
160
18
180
1)
Recommended torques for bolts of fastening class 8.8.
M
= Torque given in Newton meters.
GA
Fig. 5-5:
Mounting holes
Note:
Avoid...
• pinching or jamming the centering (pilot) diameter on the
shaft side of the motor installation.
• damaging the insertion fitting on the system side.
Operating Instructions
IndraDynA_Befestigungsbohrungen.eps
1)
Thread
Hole
Type
M
[Nm]
Ø [mm]
GA
M12
87
11
12
M16
215
14
14,5
5-7
B35 (Foot assembly)
1)
Thread
Type
M
[Nm]
GA
M10
51
M10
51
M12
87

Publicidad