IndraDynA_ATEX
Grounding Conductor
DOK-MOTOR*-IDYN*A*ATEX-IB02-D5-P
Danger of explosion due to improper handling
when connecting the motor!
⇒ The junction to/on the motor drive device must be
located outside of the area subject to explosions.
DANGER
Note:
Observe the following when connecting the encoder:
• The encoder housing on the motor may no longer be
opened! Do not remove any of the screws on the encoder
housing.
connected with the motor encoder at the factory.
• Work may be carried out only if the electrical system is not
under power.
• Heed the information in the project planning manual for the
control device as well as the details in the project planning
manual of the motor for connection assignment in the
DOK-MOTOR*-MAD/MAF****-PRxx-xx-P,
"Encoder Connection".
Danger of explosion due to improper handling
when connecting the motor!
⇒ The ground conductor on the motor must be
additionally connected to the protective conductor
WARNING
with a separate cable with 4 mm² cross-section.
The motors for areas subject to explosions have an additional ground lug
on the motor flange for this purpose. Use the grounding cable to connect
the ground-reference lug of the motor with the ground reference of the
machine or system and tighten the screw connection.
(1):
Ground-reference lug to connect the grounding conductor
Fig. 5-8:
Grounding conductor
Operating Instructions
The
connection
cable
5-11
has
already
been
Chapter
8.7
EEx_Potentialausgleich.eps