General Information; Operating Principle; General Characteristics; Weight And Dimensions Of The Cdc-Vma 20 Console - Leroy-Somer VARMECA-20 Instrucciones De Parametrización

Motores y motorreductores con variador incorporado
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

LEROY-SOMER

1 - GENERAL INFORMATION

• This manual describes how to set the parameters
of the VARMECA A20 and B20 drives irrespective
of their software differences.
• The operating characteristics are described in
sections 2.5 and 4 "VARMECA 20 parameters" and
"Wiring diagrams".
• The VARMECA A20 and B20 version number
appears on the label situated under the main connection
block.
• When using the VARMECA 20 parameter-setting
tools, the precautions described in the installation and
maintenance manual, Ref. 3481, should be applied.

1.1 - Operating principle

This manual describes access to the parameter settings of the
VARMECA 20 range via a CDC-VMA 20 console or PEGASE
VMA 20 PC software.
Combined with the VARMECA 20, these tools are used for
programming, diagnostics and displaying parameters.

1.3 - Weight and dimensions of the CDC-VMA 20 console

28
20
9
Weight: 0.3 kg
48
PARAMETER SETTING MANUAL
VARMECA 20
Variable speed motors and geared motors
GENERAL INFORMATION
5
P01
FMIN.
P02
REF 0V 4MA
ETALONNAGE CONSIGNE MIN. HZ
P03
F MAX.
P04 REF 10V 20MA
ETALONNAGE CONSIGNE MAX. HZ
P05
ACCEL.
P06
DECEL.
P07
STOP MODE
0 = ROUE LIBRE
P10
U / F
0 = FIXE
P11
BOOST
P23
F MOT .
LECTURE FREQUENCE MOTEUR
P24
I MOT .
LECTURE COURANT MOTEUR A/10

1.2 - General characteristics

1.2.1 - "CDC-VMA 20 console" option
The kit comprises:
- 1 connection cable (length = 3m) to connect to the
VARMECA 20
- 1 console with digital LCD display - 2 lines of 16 characters
- 1 parameter setting manual
1.2.2 - "PEGASE VMA 20 PC software" option
The kit comprises:
- 1 connection cable (length = 3m) to connect to the
VARMECA 20
- 1 CD-ROM for loading the software onto a PC
- 1 parameter setting manual
Minimum PC configuration:
- Pentium 100 MHz or equivalent
- 8 Mb of RAM
- Windows 95/98/NT/2000
165
FREQUENCE MIN.
HZ
MIN. FREQUENCY
HZ
MIN. FREQUENZ
MIN. REF. SCALING
HZ
ABGLEICH SOLLWERT MIN.
FREQUENCE MAX.
HZ
MAX. FREQUENCY
HZ
MAX. FREQUENZ
MAX. REF. SCALING
HZ
ABGLEICH SOLLWERT MAX. HZ
RAMPE ACCEL.
S
ACCEL. RAMP
S
HOCHLAUF RAMPE
RAMPE DECEL.
S
DECEL. RAMP
S
AUSLAUF RAMPE
MODE D'ARRET
STOPPING MODE
HALTE MODUS
1 = RAMPE
0 = FREE WHEEL
1 = RAMP
0 = FREILAUF
LOI U / F
U / F RATIO
U / F KENNLINIE
1 = DYNAMIQUE
0 = FIXED
1 = DYNAMIC
0 = FEST
BOOST
%
BOOST
%
HZ
MOTOR FREQUENCY STATUS HZ
MOTOR FREQUENZ ANZEIGE HZ
MOTOR CURRENT STATUS A/10
MOTOR STROM ANZEIGE A/10
3532 - 05.2004 / f
CDC
-VMA 20
HZ
HZ
HZ
S
S
1 = RAMPE
1 = DYNAMISCH
BOOST
%
MEM.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cdc-vma-20

Tabla de contenido