LEROY-SOMER
Variable speed motors and geared motors
Display
P54 PI DECAL
PI offset in 1/8 Hz steps
P55 REF.PI
PI reference reading
P56 INPUT PI
PI feedback reading
Signals operation of the
pump in configuration 5
P57 ALARM
OK = No fault
UNDER P1 = Underpressure fault
ALARM Q = Flow alarm
Value of the preset reference in
P58 VP5
configuration 5
Conversion factor for direct reading
P59 BAR FACTOR
in m. bars on the CDC - VMA 20 console
Enabling of the "MATERIALS HANDLING"
configuration
*
P60 CONTROL DYN.
ON = configuration enabled
OFF = configuration disabled
P61 FD BRAKE
*
Brake release frequency
P62 FB BRAKE
*
Brake engage frequency
Brake release time delay
P63 TD BRAKE
*
unit = 0.01s
Magnetisation time delay
P64 TORQUE
*
unit = 0.01s
DC injection time delay
P65 T DC INJECT.
at the end of deceleration
*
unit = 0.01s
Brake engage time delay
P66 TB BRAKE
*
unit = 0.01s
Level of DC injection at the end
P67 UC DC INJECT.
of deceleration
*
unit = % of the motor rated voltage
Current threshold prior to brake release
P68 ID BRAKE
*
unit = % of the motor rated current
Enabling of the VMA ESFR option card
P69 VMA ESFR
ON = configuration enabled
*
OFF = configuration disabled
Assignment of additional logic input
P70 N13
terminal 13. VP3-1 = Preset speed 3
*
D. BRAKE = Electrical brake release
Current threshold which trips
P71 LEVEL IN
the torque limiting fault
*
unit = % of the motor rated current
Trip time after exceeding the current
P72 T LEVEL IN
threshold unit = 1s
P80 I NEG CTRL
*
Reserved for LEROY-SOMER
P81 F_MAX I Lim
*
Reserved for LEROY-SOMER
P82 F_min I Lim
*
Reserved for LEROY-SOMER
*
P83 OFFSET I Lim
Reserved for LEROY-SOMER
*
P84 STEP F IF I Lim
Reserved for LEROY-SOMER
Ramp freezing trip value after exceeding
P86 LEVEL U P07
the voltage threshold if P07 = "AUTOMATIC"
unit = V
Assignment of terminal 9 to management of
P87 EXT FAULT N9
an external fault
P90 LOG1VARMECA
VARMECA software version (year)
P91 LOG2VARMECA
VARMECA software version (week)
P92 LOG2VARMECA
VARMECA software version
P93 LOG CDC_VMA
Console software version
*
P28 CAL_MOT
VARMECA 20 rating reading
P29 CODE
Access code
*
This parameter can be modified if the VARMECA is powered up and a stop command has been issued.
PARAMETER SETTING MANUAL
VARMECA 20
COMMISSIONING THE CDC-VMA 20 CONSOLE
Description
Adjustment range
VMA A20
VMA B20
0 to 5Hz
0 to 25000
0 to 25000
OK
Not available
UNDER P1
ALARM Q
0 to 100% of
the sensor value
1 to 20
ON or OFF
1 to 20Hz
1 to 20Hz
0 to 100
0 to 100
0 to 1000
0 to 200
Not available
0 to 100 %
0 to 100 %
ON or OFF
VP3-1
D.BRAKE
0 to 100 %
0 to 120
ON / OFF
Not available
0 to 220 Hz
Not available
0 to 49 Hz
Not available
0 to 100 %
Not available
0 to 16
Not available
0 to 800V DC
Not available
ON or OFF
Not available
Version A
Version B
Reserved for LEROY-SOMER
3532 - 05.2004 / f
Factory setting
0
0 to 1000
0 to 1000
0
1
OFF
6
2
10
10
0
20
0
0
OFF
VP3-1
0
0
0
0
0
0
6
700
OFF
Version A or B
53