Operation; Starting The Engine - GMC GGEN2000 Manual Del Usario

Generador a gasolina
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 74
If extension cords are used to connect earthed devices to the generator, earthed
extension cords of sufficient cross section must be used
Pre-operational checks
• Assess the location:
Note: Ensure the device is set up on even ground in a well-ventilated, safe location, where
it does not interfere with your work, other machines or where it could become a threat to
other people.
WARNING: ONLY set up this generator on solid ground. NEVER
place the generator on top of a work platform, scaffolding or
other elevated contraptions. Vibration may cause the generator
to move and fall off, and fasteners of scaffoldings may vibrate
loose. Metal parts of scaffoldings could become live if the device
malfunctions.
WARNING: This generator MUST NOT be set up where it
can pose a risk to anybody in its vicinity. It MUST NOT be set
up where children or pets can gain access to it, or where the
sound and vibration emitted is unacceptable. NEVER set up
the generator in wet, damp or dusty locations, where it can be
rained on, or where exhaust fumes may accumulate.
• Check the engine oil level:
Note: Always place the generator on a level surface before
checking oil/fuel levels.
1. Ensure the Engine Switch (1) is in the 'OFF' position
2. Remove the dipstick from the Engine Oil Fill Point (8) by
rotating it anticlockwise
3. Wipe off the dipstick, and re-insert into the Engine Oil Fill
Point (as shown in Fig. B)
4. The dipstick should be nearly completely covered by oil
5. Top up with suitable engine oil (see 'Specification'), if the oil
level is low
Note: This generator features a low-oil sensor that prevents
the engine from starting if oil levels are low.
Check the fuel level:
1. Check the Fuel Gauge (24) to ensure the Fuel Tank (20)
holds sufficient fuel
2. Refill if needed, as described in 'Filling with fuel'

Operation

WARNING: During the first 20 hours of operation, a new generator should only be used to
75% of its electrical capacity. This is crucial to breaking in the engine, and overloading during
this period will shorten the service life of the generator. After the break-in period, the engine
oil should be changed. Damage done by overloading the device during the break in period is
not covered by warranty.

Starting the engine

WARNING: NEVER start the generator with appliances attached to its receptacles. This can
lead to dangerous situations due to electrical devices starting up unattended, it may shorten
the service life of the generator, and cause damage to the attached appliances.
1. Ensure no appliances are attached to either of the 110V Plug Sockets (3) or 230V Plug
Sockets (6)
2. Toggle the Circuit Breaker (7) to the 'OFF' position
3. Toggle the Engine Switch (1) to the 'ON' position
4. Turn the lever of the Fuel Shut-Off Valve (17) to the 'ON' position (vertical)
5. Push the Choke Lever (13) all the way to the left, into the cold-start position (see label on
the side of the Generator Frame (9))
Note : DO NOT use the choke if the engine is already hot, or when using the generator in high
ambient temperatures.
6. Lightly pull on the Recoil Starter Cord (16) until you feel
resistance, then pull the cord sharply to start the engine
WARNING : Bring the Recoil Starter Cord back gently. DO NOT
let go of the cord, as this would let the handle return sharply
against the engine cover, potentially causing damage.
WARNING : Never attempt to pull out the Recoil Starter Cord
when the engine is running! This causes damage to the starter
mechanism and engine.
Note : When starting the engine for the very first time, when
the fuel system has been drained, or after the generator has been allowed to run empty,
it may be necessary to pull the Recoil Starter several times. Restarting the engine should
require only one or two pulls of the starter cord. Refer to the 'Maintenance' section, if starting
difficulties occur.
7. As the engine begins to heat up, slowly return the Choke Lever to the opposite position
(right)
11
GB

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido