Electrical Connections - Whirlpool Bath

Risk of electric shock. Connect only to a circuit
protected by a GFCI.
When using electrical products, basic precautions
should always be followed:
Always follow local building and electrical codes.
Grounding is required. The unit should be
installed and grounded by a qualified electrician.
Two separate GFCI protected circuits are required.
A separate, 120VAC, 20 Amp GFCI circuit is required for
the pump/motor.
A separate, 120VAC, 15 Amp GFCI circuit is required for
the heater.
Risk of component overheat. Do not use electric extension cord to power this unit.
Operating the motor/pump without enough water in the bathtub can cause leaking and permanent damage.
At initial startup, the 7 button electronic control system enters an automatic self diagnostic program for 15-20
seconds. During the diagnostic program, the system will not accept user commands.
Pump/Motor and Heater
For the pump/motor, install a 120VAC, 20AMP,
1
GFCI duplex outlet to the stud wall underneath the
bathtub at 4˝ (101mm) above the floor. The duplex
outlet is not supplied.
The duplex outlet must be mounted 4˝ (101mm)
above the floor line, or in accordance with local
building and electrical codes.
Using a #8 solid copper wire, ground the pump
2
motor to the house electrical panel, or approved
local ground. A grounding lug is provided on the
pump motor
For the heater, install a 120VAC, 15 AMP RATED
3
GFCI single outlet to the wall stud underneath the
bathtub, at least 4˝ (101mm) above the floor. The
single outlet is not provided.
With a #8 solid copper wire, ground the heater to
4
the house electrical panel or approved local bond. A
grounding lug is provided on the heater.
At initial start-up, and before each use thereafter with power ON, push the GFCI test button. The reset button
5
should pop out.
Push this button in to reset. If the interrupter fails to operate in this manner, there is a ground current flowing or a
device malfunction, indicating the possibility of electrical shock.
Turn OFF power and do not use the bathtub until the source of the problem has been identified and corrected.
Installation and Operation
Reset
Test
Power Cord from Control
Box to GFCI Circuit
www.jacuzzi.com
(101mm)
Power Cord from Heater
T M
Box to GFCI Circuit
Heater
Page 9