Quick Parameter Reference, Faults and Alarms
Param.
Description
P0219
Delay for Zero Speed
Disable
P0220
LOC/REM Selection
Source
P0221
LOC Reference Selection
P0222
REM Reference Selection
P0223
LOC FWD/REV Selection
P0224
LOC Run/Stop Selection
P0225
LOC JOG Selection
P0226
REM FWD/REV Selection
P0227
REM Run/Stop Selection
P0228
REM JOG Selection
P0229
Stop Mode Selection
8 | CFW700
Adjustable Range
0 to 999 s
0 = Always LOC
1 = Always REM
2 = LR Key LOC
3 = LR Key REM
4 = DIx
5 = Serial LOC
6 = Serial REM
7 = CO/DN/DP LOC
8 = CO/DN/DP REM
9 = SoftPLC LOC
10 = SoftPLC REM
0 = HMI
1 = AI1
2 = AI2
3 = Sum AIs > 0
4 = Sum AIs
5 = Serial
6 = CO/DN/DP
7 = SoftPLC
Refer to the P0221 options
0 = Forward
1 = Reverse
2 = FR Key FWD
3 = FR Key REV
4 = DIx
5 = Serial FWD
6 = Serial REV
7 = CO/DN/DP (H)
8 = CO/DN/DP(AH)
9 = SoftPLC (H)
10 = SoftPLC (AH)
11 = AI2 Polarity
0 = I/O Keys
1 = DIx
2 = Serial
3 = CO/DN/DP
4 = SoftPLC
0 = Inactive
1 = JOG Key
2 = DIx
3 = Serial
4 = CO/DN/DP
5 = SoftPLC
Refer to the P0223 options
0 = I/O Keys
1 = DIx
2 = Serial
3 = CO/DN/DP
4 = SoftPLC
Refer to the P0225 options
0 = Ramp to Stop
1 = Coast to Stop
2 = Fast Stop
3 = By Ramp with Iq = 0
4 = Fast Stop with Iq = 0
Factory
User
Propr.
Setting
Setting
0 s
2 = LR Key
LOC
0 = HMI
1 = AI1
2 = FR Key
FWD
0 = I/O Keys
1 = JOG
Key
4 = DIx
1 = DIx
2 = DIx
0 = Ramp
to Stop
Groups
Pag.
12-8
cfg
I/O
13-22
cfg
I/O
13-23
19-9
19-18
19-22
cfg
I/O
13-23
19-9
19-18
19-22
cfg
I/O
13-23
19-29
cfg
I/O
13-24
19-26
19-29
cfg
I/O
13-24
cfg
I/O
13-23
19-29
cfg
I/O
13-24
19-26
19-29
cfg
I/O
13-24
cfg
13-24