- After the alignment check by placing an obstacle that the red LED turns off
and that at the same time the dual-color LED EDGE PHOT associated with it
during memorization shines green on the MASTER Wi-Fi FR for the time that
the obstacle is present.
- On the MASTER Wi-Fi FR card, LED DL3 should also be off indicating a proper
exchange of the dedicated input with the PHOT on the control panel.
- Repeat the procedure on the other installed NOVA Wi-Fi photocells.
- Perform a function check of all the installed photocells, activating the movement
of the automation and checking that by placing an obstacle the automation stops/
reverses when closing, or stops/continues to open when opening.
TOUCH Wi-Fi and VERTIGO Wi-Fi SYSTEM CHECK
- Activate the contact of a TOUCH Wi-Fi or a VERTIGO Wi-Fi (ex: safety device
number 3).
- On the MASTER Wi-Fi FR check that the corresponding LED EDGE PHOT 3
flashes green and that the paired LED DL2 momentarily turns off and then turns
on.
ATTENTION: after receiving the first signal, other signals are ignored for 2
seconds. If there is a signal in these 2 seconds it will be from the LED EDGE
PHOT 3 which turns green.
- Repeat the LED activation check on the MASTER Wi-Fi FR activating the other
TOUCH Wi-Fi and VERTIGO Wi-Fi installed.
- Perform a final check of all of the strips installed, activating the movement of the
automation and ensuring that upon impact with the strip the automation stops/
reverses movement.
ANTENNA 868MHz
In order to communicate with 868 MHz Wi-Fi safety devices, MASTER Wi-Fi FR is
equipped with a piece of electric wire that acts as an antenna linked to the
J8 terminal. If it is necessary to improve the radio signal
(for example, with MASTER Wi-Fi FR inserted in the
SUPER motors or MASTER Wi-Fi FR installed in a metallic
connector), connect the 868.3 MHz antenna (code ACG5451)
to the J8 terminal, ensuring the correct connection of the
central wire and the earth wire, and position it in such a
way so that it is "in view" of all safety devices.
To ensure the system functions correctly it is necessary that between the
MASTER Wi-Fi FR and the safety devices there are no obstacles such as
reinforced cement walls, iron surfaces, etc. that could obstruct the radio
communications and consequently reduce the battery life of the safety
devices.
ANTENNA 433MHz
For commands working at 433,92 MHz, connect it to terminals 1-2.
NOVA Wi-Fi AND VERTIGO Wi-Fi PHOTOCELL ALARM SIGNAL CHECK
Check that by taking the battery out of the photocell receiver with micro-switch,
for example 3 in the ON on position, and commanding the door to open, the dual-
color LED3 on the MASTER Wi-Fi FR alternates green and red , while LEDs DL2
and DL3 turn off, and that the buzzer emits an alternating sound for 1 minute.
Repeat the check for any other photocell receivers installed.
Note: if when removing the battery and commanding the door to open the buzzer
on the MASTER Wi-Fi FR does not sound, micro-switch 3 on the MASTER Wi-Fi
FR is in the OFF position (go-ahead not enabled). Turn it to ON.
TOUCH Wi-Fi STRIP ALARM SIGNAL CHECK
Check that by taking the battery out of the transmitter with micro-switch, for
example DIP3 in the ON position, the dual-color LED EDGE PHOT 3 on the
MASTER Wi-Fi lights flashing red while LED DL2 turns off, and that the buzzer
emits every 3 seconds sound for 1 minute.
Repeat the check for any other strips installed.
Note: if the battery is removed and the buzzer on the MASTER Wi-Fi FR does not
sound, micro-switch 3 on the MASTER Wi-Fi FR is in the OFF position (go-ahead
not enabled). Turn it to ON.
WARNING (replace the batteries)
The WARNING tells the user of the immediate need to replace the batteries.
When battery power reaches 2,3V for NOVA Wi-Fi and 3V for TOUCH Wi-Fi, the
photocell receiver or the strip signal the MASTER Wi-Fi FR via radio of the low
battery status and activates the BUZZER of the MASTER Wi-Fi FR with a sound
every 3 seconds for 1 minute.
The warning is renewed for 1 minute if a command is given to the door.
The dual-color LED on the MASTER Wi-Fi FR corresponding to the photocell or
the strip with the low batteries emits a constant red light.
The SPARK Wi-Fi blinker (if available) indicates the warning by emitting 2
consecutive flashes followed by a pause for 3 seconds for the duration of
the opening or closing of the door.
The system is still operational during these signals, but it is advantageous to
replace the batteries as soon as possible in order to avoid a full stop of the
door operation which happens when the batteries reach 2,0 V for NOVA Wi-Fi/
VERTIGO Wi-Fi and 2,7 V for TOUCH Wi-Fi.
ALARM (batteries completely exhausted or not working)
The alarm activates when the batteries are completely exhausted (2V for NOVA
Wi-Fi/VERTIGO Wi-Fi and 2,7V for TOUCH Wi-Fi) or when they stop working.
On MASTER Wi-Fi FR the LEDs DL1, DL2 and DL3 turn off MASTER Wi-Fi FR
blocks the automation.
On MASTER Wi-Fi the dual-color LED corresponding to the photocell or the strip
with the low or non-functioning batteries flashes red. The BUZZER emits a sound
every 3 seconds for 1 minute, while the SPARK Wi-Fi blinker (if available)
signals the alarm status by emitting emitting 2 consecutive flashes followed
by a pause for 3 seconds, notifying the user that the batteries must be
replaced or repaired.
The alarm is renewed for 1 minute if a command is given to the door.

REPLACING THE BATTERIES

The lifespan of the 1.5 V AA batteries used in the safety devices is about 3 years.
In case it is required to replace the batteries, it will not be necessary to re-program
the photocells, nor any other RIB Wi-Fi accesories.
- Identify the safety device with the exhausted batteries by checking the diagnostic
of the LED EDGE PHOT on the MASTER Wi-Fi FR.
- Using the number on the side of the dual-color LED EDGE PHOT which is
flashing red or that emits a constant red light identify the number of the safety
device with the exhausted batteries.
- Find the NOVA Wi-Fi or TOUCH Wi-Fi device with the adhesive strip bearing the
identification number corresponding to the number of the dual-color LED which
is in alarm status on the MASTER Wi-Fi FR.
- Replace the batteries, checking that the polarity is correct.
- Push button PROG TX on the NOVA Wi-Fi or TOUCH Wi-Fi to restart the
MASTER Wi-Fi FR.
- The buzzer on the strip of the MASTER Wi-Fi FR will turn off (if in alarm status)
and the LEDs DL1-DL2- DL3 will come on. The dual-color LED corresponding to
the safety device with the replaced batteries will turn off.
The automation is now ready for safe operation.
ATTENTION: Please remember that batteries must be disposed of properly
according to current standards. In case of disposal of the safety devices please
remember to remove the AA batteries and dispose of them properly
TOTAL REMOVAL PROCEDURE FOR MEMORIZED SAFETY DEVICES
To perform a total removal of the safety devices (NOVA Wi-FI and TOUCH Wi-FI)
recorded in the MASTER Wi-Fi FR memory just push and hold the button PROG.
RX for 10 seconds.
After 10 seconds all of the dual-color LEDs (from EDGE PHOT 1 to EDGE PHOT
6) will flash alternately 6 times, indicating successful removal.
Afterwards the dual-color LED EDGE PHOT and LEDs DL2 and DL3 will turn off.
ATTENTION: WITH LED DL1, DL2 AND DL3 OFF AUTOMATION DOES NOT
WORK.
REMOVAL PROCEDURE FOR A SINGLE SAFETY DEVICE (PHOTOCELL OR
STRIP)
In order to remove a single memorized safety device on the MASTER Wi-Fi FR,
use the following procedure:
- Push the button PROG. RX one or more times to select the dual-color LED
EDGE PHOT which begins flashing green, corresponding to the safety device
to be eliminated.
- After selecting the safety device, push and hold the button PROG. RX for 10