ROUBLESHOOTING
The gate would not move, the buzzer is emitting an alternating sound, and one of the LED is blinking red/
green.
The gate would not move, the buzzer is emitting an alternating sound, and one of the LED is blinking red/
green, OR
the gate is trying to open/close, but stops almost immediately, the buzzer is emitting an alternating sound,
and one of the LED is blinking red/green.
All of the LEDs on the MASTER Wi-Fi FR are off
During memorization of the safety devices the buzzer sounds for 3/5 second
During memorization of the safety devices the buzzer sounds 2 twice
When giving a command the buzzer sounds 3 times
When giving a command the buzzer sounds 4 times
The buzzer sounds 5 times when the strip connected to the photocell receiver is pressed
When giving a command the buzzer sounds 5 times
The buzzer emits a sound every 3 seconds and the blinker during the gate operation flashes 2 times in
succession followed by a pause of 3 seconds for 1 minute and one of the dual-color leds is ignited red fixed
The gate doesn't move, the buzzer emits a sound every 3 seconds and the blinker flashes 2 times in
succession followed by a pause of 3 seconds for 1 minute and one of the dual-color leds lights flashing red
LED DL2 is off and one of the dual-color LED EDGE emits a constant green light
The buzzer does not sound when the batteries are removed from the strip
The door does not open or close and one of the dual-color LEDs emits a constant green light
The door does not open or close, the buzzer emits a sound every 3 seconds and the blinker flashes 2
times in succession followed by a pause of 3 seconds for 1 minute and one of the dual-color LEDs lights
flashing red
The strip connected to the photocell transmitter or receiver does not work as a safety device
T
ECHNICAL SPECIFICATIONS
- POWER
- APPLICABLE TENSION ON CONTACT J4 120/220/230V 50/60Hz
- APPLICABLE TENSION ON CONTACT J2 12/24V ac/dc
- ABSORPTION AT REST
- MAXIMUM ABSORPTION
- WORKING TEMPERATURE
- SIZE
- WEIGHT
PROBLEM
12/24 Vac/dc
40 mA
100 mA
-20°C ÷ +60°C
125x55x28 mm
0,090 kg
If two MASTER Wi-Fi FR, installed at a distance of about 20 m from one another, are commanded simultaneously,
their communication and check signals with the accessories can overlap and interfere with each other, causing
the systems to go into alarm. Move the two MASTER Wi-Fi FR away from each other over the 20 m.
Failed control between MASTER Wi-Fi FR and the safety accessories, either the photocells or the safety
edges:
- Install the 868MHz aerial (code ACG5451) on the MASTER Wi-Fi FR to guarantee the correct
communication between the MASTER Wi-Fi FR and the safety accessories installed.
Attention: The aerial must be placed in sight of all the safety accessories installed.
If the indication of failure persists, check the level of charge of the batteries, and if not adequate, replace
them.
Ensure that 12 or 24 V ac/dc power is present to the power feed terminals of the MASTER Wi-Fi FR
It has been tried to memorize a safety device with wrong microswitch.
Verify that the dual-color led that flashes on MASTER Wi-Fi FR corresponds at the safety device
microswitch to memorize.
A safety device is already in the memory
- No safety device has been memorized, memorize at least one, OR
- The DIP corresponding to the safety devices memorized on the MASTER Wi-Fi FR card are OFF. Turn
them to ON
Possible cable missing between the MASTER Wi-Fi FR and the door control card:
- Blinker to card connection wires detached, OR
- Strip to card connection wires detached, OR
- Photocell to card connection wires detached
Contact configuration error with the strip connected to the photocell receiver
- Resistance not connected in series with the N.C. contact of the strip connected to the photocell receiver,
OR
- Wires detached on the strip with N.O. contact, OR
- Resistance not connected in series with the N.C. contact of the strip, OR
- Wires detached on the strip with N.O. contact connected to the photocell receiver
Replace the batteries of the photocell(s) or the strip(s) as they are low
Replace the batteries of the photocell(s) or the strip(s) as they are exhausted
- Wires detached on the strip with N.C. contact, OR
- Ensure that there is resistance of 8,2kΩ in series with the N.O. contact of the strip connected to the
photocell receiver
Ensure that the micro-switch on the MASTER Wi-Fi FR corresponding to the strip is in the ON position
- Photocell is not aligned or it is engaged. The batteries in the photocell transmitter are exhausted, OR
- Resistance of 8,2 kΩ is not connected in series with the N.C. contact or in parallel with the N.O. contact of
the strip connected to the photocell transmitter, OR
- Resistance of 8,2 kΩ is not connected in parallel with the N.O. contact of the strip connected to the
photocell transmitter
Photocell or strip receiver batteries are exhausted
Check the correct setting of the jumper of the photocell transmitter/receiver. If the jumpers are correctly
setting, remove and put again the batteries.
SAFETY DEVICES AND SIGNALING RADIO FREQUENCY SIGNAL
TECHNICAL INFORMATION
- FREQUENCY
- SENSITIVITY
- EMITTING POWER
- MODULATION TYPE
- RANGE
COMMAND ACTIVATION RADIO FREQUENCY SIGNAL TECHNICAL
INFORMATION
- FREQUENCY
- SENSITIVITY
- MODULATION TYPE
- RANGE
25
25
CHECK
868,3 MHz
-108 dBm
<25 mW
FSK
20 m in open spaces
433,92 MHz
-107 dBm
OOK
100 m in open spaces with antenna
G