Selecting Display Data Items
The arrow keys are used to select the data items that are shown on each display line as
follows:
Right Arrow
● Upon pressing the <Right Arrow> key, a selection cursor will appear under the channel
● Pressing the <Right Arrow> key once again will cause the selection cursor to move to the
Up/Down Arrows
● Once a display line is selected as described above, use the <Up or Down Arrow> keys to
When satisfied with the item currently displayed, stop scrolling and use the <Right Arrow>
key to move to the other display line. Once the display is set up in the desired configuration,
execute no further commands and the selection cursor will eventually turn off.
Note
The System Menu can be invoked at any time by pressing the <ENTER> key.
Serial Interface Display
The data menu displays provided via the FST020 serial interface mimic the more complex
SITRANS F 1010 graphic displays. Display and data item selection in these menus are
accessed via the <Up/Down Arrow> keys only.
Note
The 2 x 16 alphanumeric display is not available via the serial port.
FST020 IP65 NEMA 4X Quick Start
Operating Instructions, 03/2012, A5E03086489-05
indicator numeral (i.e., 1).
other display line and so forth.
Note
The selection cursor will turn off after a period of inactivity.
scroll through the available data items at the selected display line. These measuring
parameters may include Vs M/S, Velocity F/S, Signal mV, Valc, Aeration, Flow, Total
Flow, etc.