INITIAL OPERATION
BASIC SETTING
Proceed step by step. If you are not sure, start again at the beginning. Take sufficient time to make these settings.
1. Are all components required for operation connected? Motors, photocells, safety contact strip, stop switch.
2. Make sure that nobody is present in the range of the gates.
3. Check/Adjustment/Correction of cams on both motors
Gate closed:
Gate at approx. 45°:
Gate open:
(for adjustment refer to mechanical installation)
BASIC SETTING:
1. Press buttons P1, P2 and P3 simultaneously for approx. 2-3 seconds until yellow LED flashes.
2. Monitor the gate. Press and hold P1 for 1-2 seconds. The wing with motor 1 opens. If motor 1 closes, it is wired incorrectly and
the red and blue wires of the motor cable must be inverted. (Caution: Disconnect Power!)
Repeat steps 1 and 2. Leave gate/s in partially open position.
NOTE: General operation – if you release the button, the gate will immediately stop. By pressing the button again the gate will
move in the opposite direction until you release the button, and so on.
3. Press and hold P2 for 1-2 seconds. The wing with motor 2 must open. (Do not open gate completely, only short distances.)
If motor 2 closes, it is wired incorrectly and the red and blue wires of the motor cable must be inverted.
(Caution: Disconnect Power!)
Repeat steps 1 and 2. Leave gate/s in partially open position.
NOTE: The control board is active for this manual setting mode for approx. 20 seconds. If necessary, start again by pressing P1,
P2 and P3 simultaneously.
Now check the following:
1. If both operators connected open both wings completely.
2. Both wings must open completely. Do not open the wings too far! A gate stop in OPEN position is required.
Caution: Gate must not come in contact with operator (i.e. when operator has been released for manual operation)
Wait until learn-LED goes out (20 seconds after a button was pressed).
PROGRAMMING TRAVEL DISTANCES "SIMPLE I"
NOTE: only with stops in OPEN and CLOSE position
1.
Wings must be closed
2.
Press P1 until wing / motor 1 starts opening (learn-LED flashes resp. glows)
Automatic programming starts (slow travel)
Wing 1 moves to the stop in OPEN position
Wing 2 moves to the stop in OPEN position
Then wing 2 moves to the stop in CLOSE position.
Then wing 1 moves to the stop in CLOSE position.
When the learn-LED goes out the programming has finished.
PROGRAMMING TRAVEL DISTANCES "ADVANCED"
NOTE: In this mode P1 must be pressed 9 times. With every time the button is pressed a position (time) is stored. (This allows
programming of SOFT-STOP (slow travel) in order to adjust to application. Long or short phases of SOFT-STOP are possible.
1.
Both wings must be closed.
2.
Press P1 and P2 for approx.5-6 seconds until wing / motor 1 starts opening.Release buttons!!!
3.
Press P1 again. SOFT-STOP for wing / motor 1 in OPEN direction starts at this point.
4.
Press P1 again when OPEN position is reached.Now wing / motor 2 starts automatically to open.
5.
Press P1 again. SOFT-STOP for wing / motor 2 in OPEN direction begins at this point.
6.
Press P1 again when OPEN position is reached. Now wing / motor 2 starts closing automatically.
7.
Press P1 again. SOFT-STOP for wing / motor 2 in CLOSE direction begins at this point.
8.
Press P1 again when CLOSE position is reached. Now wing / motor 1 starts automatically to close.
9.
Press P1 again. SOFT-STOP for wing / motor 1 in CLOSE direction begins at this point.
10.
Press P1 again when CLOSE position is reached.
Done!
switch free
switch fully pushed (cam operates switch)
switch free