NOTE: If one wing reaches a stop and button P1 is not pressed, then the motor moves towards the stop and stores this position
automatically.
COMPLETION OF INSTALLATION / PROGRAMMING
Once the travel distances are programmed, the remote controls can be programmed as well.
(Refer to PROGRAMM / DELETE REMOTE CONTROLS).
1. Operate the gate with a remote control or with a connected switch and monitor the direction. Close the gate again WITHOUT
any interuptions.
2. If all adjustments are done, check operation of photocells, switch, flashing light, remotes, accessories, etc.
3. Advise people using the gate with regard to gate operation, safety functions and how to release the gate in order to operate it
manually.
TIMER TO CLOSE
NOTE: Only possible with connected photocells (1 + COM). Time frames from 2 seconds up to 120 seconds are possible.
Activate:
1.
Press and hold P2 until yellow LED starts flashing
2.
Now count the time you wish to program
3.
Press P2 again. Done!
Deactivate:
1.
Press and hold P2 until yellow LED starts flashing.
2.
Press P3. Yellow LED goes out. Done!
TORQUE OF MOTOR
Thrust of the motor is set automatically while programming
the travel distance. Thrust can only be modified by
programming the travel distance again. If gate movement is
impeded by weather or changes to the installation (rust or
inappropriate lubrication) it may have to be repaired.
The control board complies with the latest EU
guidelines. One of these guidelines specifies that the
closing forces at the gate edge must not exceed 400 N (40 kg) for
the last 500 mm before the door is CLOSED. Above 500 mm, the
maximum force at the gate edge must not exceed 1400 N (140 kg). If
this cannot be ensured, a contact strip must be mounted on the gate
at a height up to 2.5 m or on the pillar on the opposite side
(EN12453).