Initial programming sequence
Before starting...
Check that the motor is compatible with the associated brackets or accessories and that it is
correctly installed.
Switch off the power supply.
Connect the motor according to the information in the table below.
Input Voltage
120V AC
Series
6-700-CM-XXXXX
220V AC
Series
6-700-CN-XXXXX
1
Pair the motor with the remote control.
2
Check the direction of rotation of the motor and
change it if needed.
3
Set upper and lower limits depending on the
installation requirements.
IMPORTANT:
The limits must be preconfigured during the fabrication of the shade and not during the final installation.
Optional functions
•
Adding an additional remote or "cloning" a channel
•
Changing to tilt or jog mode
¡Warning!
KEEP AWAY FROM WATER
VTi
Celtic motors are weather resistant in a protected environment (ex.: covered terrace), but not
®
waterproof and therefore the motor head should not be exposed to direct rainfall.
vertilux.com
2
© 2018. Vertilux, Ltd. All Rights Reserved. Last revised: October 2018.
Neutral
Live
White
Black
Blue
Brown
•
Deleting a single motor or channel
•
Unlinking the motor from the remote control
LOWER CABLE LOOP AVOIDS WATER INFLOW
Ground
Green
Green I Yellow
UP OR
DOWN?