INSTALACIÓN ELÉCTRICA
Wire switching outputs "Result 1 ... 4" of the CLV69x in the CDB650-204 connection module
CLV69x
U
V
Result X
GND
CLV69x
CDB650-204
Result X
Pin Y
Pin Y
Name
Result 1
13
13
RES/OUT 1
Result 2
14
14
RES/OUT 2
Result 3
16
16
RES/OUT 3
Result 4
17
17
RES/OUT 4
Specifications of the switching outputs "Result 1 ... 4"
Logic
PNP switching to supply voltage U
CLV69x default:
Result 1: Device Ready (static), logic: active high
Result 2: Good Read, 100 mm, logic: active high
Result 3: no function assigned
Result 4: no function assigned
Properties
– Short-circuit protected + temperature protected
– Not electrically isolated from U
0 V ≤ U
≤ U
Electrical
a
V
Guaranteed:
values
(U
− 1.6 V) ≤ U
V
Functional allocation for switching outputs via SOPAS-ET
configuration software.
Figura 73: Cableado de salidas conmutadas "Result 1 a 4"
74
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
Connection cable 1:1
2)
2
.
.
.
Y
1
3
12
2
M12,
11
13
4
1
5
16
17-pin,
14
10
6
9
A-coded
17
15
8
7
Terminal Z
20
21
50
51
.
V
(+ 24 V*)
V
≤ U
in the case of I
≤ 100 mA
a
V
a
1)
CDB650-204
2
U
*
IN
Shield
5
Y
Z
Name
1
GND
22
GND
3
12
2
11
13
4
1
5
16
14
10
6
9
17
8
15
7
1) Dependent on type
For CLV69x-xxx0 (without heating):
no. 6052286 (2 m)
no. 6051194 (3 m)
no. 6051195 (5 m)
For CLV69x-xxx1 (with heating):
no. 6053230 (2 m)
no. 6053231 (3 m)
no. 6053232 (5 m)
2) Pin 2 in the CLV69x-xxx1
(with heating) not connected
Load (e.g. PLC)
U
a
In the case of inductive load:
Discharge wiring:
apply free running
diode directly to
the load!