Wire switching outputs "Ext. output 1 and 2" of the CLV69x on the CDM420-0006 connection module
CLV69x
"External
Serial Aux
output 1,
(RS-232)
output 2"
Characteristic data of "External output 1 and 2" switching outputs
PNP switching to supply voltage U
Switching
(Default settings: no function,
behavior
logic: not inverted [active high])
Properties
–Short-circuit protected + temperature protected
–Not electrically isolated from supply voltage (+24 V*)
Electrical
0 V ≤ U
≤ U
a
V
values
Guaranteed:
(U
−1.5 V) ≤ U
V
Functional assignment for switching outputs
via SOPAS-ET configuration software
Figura 86: Cableado de salidas conmutadas "Entrada externa 1 y 2"
8025632/131W/2019-03-06 | SICK
Sujeto a cambio sin previo aviso
CDM420-0006
CMC600
+24 V* = U
after fuse
V
CLV69x
CDM420-0006
Output
Name
External output 1
Aux Out 1
External output 2
Aux Out 2
V
≤ U
at I
≤ 100 mA
a
V
a
+24 V* (U
)
V
Shield
6
Name
Z
GND
GND
36
Terminal Z
40
30
The CLV69x issues the output states of its "External
output 1 and 2" logical outputs via its serial AUX
interface.
Via the connecting cable, the CMC600 automatically
adopts the statuses and translates them to its
physical "AUX Out 1 and 2" outputs in the
CDM420-0006 using software.
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
INSTALACIÓN ELÉCTRICA
Load (e.g. PLC)
U
a
With inductive load:
Sweep-out circuit:
Attach a freewheeling
diode directly to the load.
6