6
INSTALACIÓN ELÉCTRICA
Wire RS-232 data interface of the CLV69x in the CDM420-0006 connection module
CLV69x
6
TxD
12
RxD
1
GND
RS-232
3
12
2
13
4
5
14
6
9
17
15
8
7
M12 male connector
17-pin,
A-coded
1) Dependent on type
For CLV69x-xxx0 (without heating):
No. 2049764 (0.9 m)
No. 2055419 (2 m)
No. 2055420 (3 m)
No. 2055859 (5 m)
For CLV69x-xxx1 (with heating):
No. 2061480 (2 m)
No. 2061605 (3 m)
No. 2061481 (5 m)
Figura 79: Interfaz de datos serie RS-232 cableada
80
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
Adapter cable
1)
9
7
5
.
.
.
S2 : RS 485
11
10 5
1
6
1
ON
16
10
OFF
15
11
D-Sub-HD female
connector,
15-pin
CDM420-0006
S2
T‒/TxD
34
485
OFF
R‒/RxD
35
GND
36
GND
Shield
6
S3: Term 422
ON
OFF
Host
RxD
TxD
GND
RS-232
8025632/131W/2019-03-06 | SICK
Sujeto a cambio sin previo aviso