6
INSTALACIÓN ELÉCTRICA
Wire supply voltage for CLV69x-xxx0 in the CDM420-0006 connection module
CDM420-0006
1
+24 V
2
GND
+24 V*
Max.
F
2 A
5
Shield
DC 18 V ... 30 V
S1 : POWER
ON
OFF
U
= DC 18 V ... 30 V at terminal +24 V =
V
U
at terminal +24 V* after switch S1, protected by internal fuse F
V
Switch S1:
ON:
supply voltage U
to CDM420-0006 and CLV69x.
U
(+24 V*) can also be engaged at terminal 29 and 39.
V
OFF:
CDM420-0006 and CLV69x separated from supply voltage.
Recommended position for all connection types.
Figura 77: Tensión de alimentación cableada para CLV69x-xxx0 (sin calefacción)
78
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
Adapter cable
+24 V*
1
F
S1
.
.
POWER
.
GND
5
10 5
1
6
Shield
15
11
D-Sub-HD
female
connector, 15-pin
(+24 V) switched via fuse as U
V
V
1)
CLV69x-xxx0 (without heating)
U
2
V
Cloning plug
.
.
No. 2062452
.
.
.
.
1
GND
3
12
2
11
13
"HOST/AUX/I/O"
4
1
5
16
14
connection
10
6
9
17
15
8
7
M12 male connector,
17-pin, A-coded
1) Adapter cable
(+24 V*)
For CLV69x-xxx0 (without heating):
No. 2049764 (0.9 m)
no. 2055419 (2 m)
no. 2055420 (3 m)
No. 2055859 (5 m)
U
V
8025632/131W/2019-03-06 | SICK
Sujeto a cambio sin previo aviso