Wire "Sensor 1 ... 6" switching inputs of the CLV69x in the CDM490-0001 connection module
a) Schema: sensor supplied by CDM490-0001
CDM490-0001
e.g. photoelectric sensor
U
51 +24 V*
V
X
Out
GND
54 SGND
6 Shield
PNP sensor
S1 : SGND
ON
OFF
CDM490-0001
Terminal X
61
62
63
64
65
66
b) Schema: sensor connected volt-free and externally supplied
CDM490-0001
e.g. photoelectric
U
sensor
V ext
U
51 +24 V*
V
X
Out
54 SGND
GND
6 Shield
PNP sensor
S1 : SGND
ON
OFF
d) Schema: switch connected volt-free
and externally supplied
Connection of the switch as under b)
Figura 95: Entradas conmutadas "Sensor 1 a 6" cableadas
8025632/131W/2019-03-06 | SICK
Sujeto a cambio sin previo aviso
Adapter cable
(I/O card)
1
+24 V*
Y
Name
.
.
Shield
.
9
S1
5
GND
6 1
5
10
11
15
15-pin
D-Sub-HD
male connector
CLV69x
Name
Pin Y
Pin Y
Sensor Z
Sensor
3
3
Sensor 1
IN 0
6
6
Sensor 2
IN 1
2
2
Sensor 3
IN 2
7
7
Sensor 4
IN 3
11
11
Sensor 5
IN 4
12
12
Sensor 6
(I/O card)
+24 V*
Name
Shield
S1
GND
Characteristic data of the switching inputs "Sensor 1 ... 6"
Switching behavior
Properties
Electrical values
INSTALACIÓN ELÉCTRICA
1)
CLV69x
2
U
1
V
Y
Sensor Z
6,64 K
U
e
3,32 K
SensGND
9
5
GND
U
= max. 32 V
10 5
1
6
e
15
11
2 "I/O" connection
15-pin
1) E.g. no. 2020302 (3 m)
D-Sub-HD
female connector
Switch S1: SGND
ON: connect GND of the switching inputs to the
GND of the CDM490-0001/CLV69x.
OFF: sensors connected volt-free to switching inputs
on the CDM490-0001/CLV69x.
Reference potential valid for all "Sensor 1 ... 6"
switching inputs and optionally
a) Schema: switch supplied by CDM490-0001
CDM490-0001
(I/O card)
51 +24 V*
X
Name
54 SGND
6 Shield
S1 : SGND
ON
OFF
Current at the input starts the
assigned function, e.g. start reading cycle.
(CLV69x default settings:
logic active high, debouncing 10 mm)
– Opto-decoupled, reverse-polarity protected
– Can be wired with PNP output of a sensor
Low:
U
≤ 2 V; I
≤ 0,3 mA
e
e
High:
6 V ≤ U
≤ 32 V;
e
0,7 mA ≤ I
≤ 5 mA
e
I N S T R U C C I O N E S D E S E R V I C I O | CLV69x
U
V
GND
+24 V*