Solar 4001 Manual Del Proprietário página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Insert (2) washers on each bolt.
Mounting Gray output power connection.
3. Positive Connection #1. Run Positive Control Cabinet Cable (terminal end Red, labeled P1) through the cable
access hole located at the back of the Battery Tray and place it over the Positive (POS, +) Terminal of Battery
#1.
4. Negative Connection #1. Run Negative 12V Quick Connect Cable (terminal end Black, labeled N1) through the
cable access hole located at the back of the Battery Tray and place it over the Negative (NEG, –) Terminal of
Battery #2.
5. Positive Connection #2. Run Positive 12V Quick Connect Cable (terminal end Red, labeled P2) through the
cable access hole located at the back of the Battery Tray and place it over the Positive (POS, +) Terminal of
Battery #1.
6. Negative Connection #2. Run Negative Cable from Gray Quick Connect (terminal end Black and labeled N2)
through the cable access hole located at the back of the Battery Tray and place it over the Negative (NEG, –)
Terminal of Battery #2.
Voltage selector cable assembly
Secure charging Quick Connect
to upper handle.
2. Mount the Output Cable (Gray) Quick Connect Assembly. The Output
Cable Quick Connect is connected to the Control Cabinet with a heavy
gauge positive cable and has a loose negative cable. To mount it to
the Battery Tray Assembly, insert two M6x40mm bolts though the
inside of the Battery Tray (with the bolts oriented such that the bolt
head is on the inside of the Battery Tray) and through the Gray Quick
Connect, situated on the outside of the Battery Tray. Place a washer
and nut on each of the (2) exposed bolts coming through the Quick
Connect and tighten both until snug.
7. Negative Voltage Selector Connection. Run Negative cable from
Voltage Selector Quick Connect (terminal end black, labeled vN)
through the cable access hole located at the back of the Battery Tray
and place it over the Negative (NEG, –) Terminal of Battery #1.
8. Positive Voltage Selector Connection. Run Positive cable from Voltage
Selector Quick Connect (terminal end black, labeled vP) through the
cable access hole located at the back of the Battery Tray and place it
over the Positive (POS, +) Terminal of Battery #2.
9. Small Diameter Wire Connections. There are (4) small diameter wires
exiting the bottom of the Control Cabinet, all terminated with ring
terminals: (1) thick red wire, (1) thick black wire, (1) thin red wire, (1)
thin black wire. In the sequence listed, run each wire through the cable
access hole and make the following connection:
– thick red wire (R1) to Positive (POS, +) Terminal of Battery #1
– thick black wire (B1) to Negative (NEG, –) Terminal of Battery #2
Charging wires should run through
Control Cabinet mounting ears.

Publicidad

Tabla de contenido
loading

Productos relacionados para Solar 4001