Maintenance (cont'd)
Battery
Stop engine when checking battery
electrolyte level. Do not check or
fill battery electrolyte level near
an open flame, sparks, or when
smoking. Battery fumes are flam-
mable and explosive, and if ignited
will result in severe injury or death.
When working on or around the battery:
• Remove jewelry, wristwatches and any other con-
ductive items. The current produced by the battery
could cause severe burns.
• Wear eye protection and gloves and handle the
battery carefully. Contact with battery acid could
cause severe burns or blindness.
Failure to observe these warnings could result in
severe injury or death.
Greenlee / A Textron Company
F20 Portable Power Unit
Battery Maintenance and Replacement
Battery is a utility style, sealed lead acid type. Clean
battery terminals and cable clamps when required. After
cleaning, coat battery terminals and cable clamps with
grease or other suitable product to reduce corrosion.
When battery replacement becomes necessary, it is
recommended that replacement battery should meet or
exceed original battery specifications; amps, cranking
power, etc.
When disconnecting battery cables, remove the black
cable first from the negative (–) battery post and then
the red cable from the positive (+) battery post.
When connecting the battery cables, attach the red
cable to the positive (+) battery post first and the black
cable to the negative (–) battery post last.
Pneumatic Tires
Inflate power unit tires to the recommended pressure
printed on the sidewalls of the tires. Do not exceed
tire manufacturer's recommended maximum pres-
sure printed on the sidewalls of the tires or rim
manufacturer's recommended maximum pressure
stamped on the rim, whichever is lower.
12
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070