Troubleshooting (cont'd)
Problem
Engine does not turn over.
Engine turns over, but does not start. No fuel in tank.
Engine lacks power, runs rough,
backfires, etc.
Tool used with power unit is
inoperative.
Greenlee / A Textron Company
Probable Cause
Battery weak or dead.
Battery cables corroded.
Electrical short, broken wire, or loose
connection.
Engine starter inoperative.
Flow ON/OFF handle in the ON
position.
Electrical short, broken wire, or loose
connection.
Flow ON/OFF valve in the OFF
position.
Tool is a closed-center system type.
No hydraulic fluid in system or fluid
level low.
Incorrect hydraulic fluid viscosity.
Hydraulic filter needs service.
Power unit components (pump,
valve etc.) worn or damaged.
Engine output insufficient. Engine
needs adjustment, tune-up, etc.
14
F20 Portable Power Unit
Probable Remedy
Recharge or replace battery.
Clean battery cable terminals or
replace cables.
Check wires and connections.
Repair or replace.
Repair or replace starter. Refer to the
engine operator's manual.
Fill fuel tank.
Move handle to the OFF position.
Check wires and connections.
Repair or replace.
Refer to the engine operator's
manual.
Refer to the engine operator's
manual.
Move flow ON/OFF valve to ON
position.
Use only open-center system tools.
Check fluid level. Fill to FULL mark.
Check system for leaks.
Use fluid viscosity recommended.
Refer to "Recommended Hydraulic
Fluids."
Replace hydraulic filter.
Repair or replace components.
Refer to the engine operator's
manual.