4. Continuity
Apo
A-HOLD
DC Voltage Measurement
Range
Resolution Accuracy
± 1 to 399.9
0.1V
± 400 to 599 1V
± 600 to 750 1V
Overload Protection:
750V
Input Impedance:
>10M
Resistance Measurement (Ohms)
Range
Resolution Accuracy
0 to 399
0.1
0.4k to 4k
0.001K
Overload Protection:
Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth. Do not use
abrasive cleaners or solvents.
Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high
temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in
the Specifications section, allow the instrument to return to normal operating conditions before using it.
Do not place equipment and its accessories in the trash. Items must be properly disposed of in
accordance with local regulations.
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
Apo
A-HOLD
ELECTRICAL SPECIFICATIONS
± (0.5% + 3 digits)
± (0.5% + 5 digits)
± (0.8% + 4 digits)
600V
WARRANTY
www.kleintools.com/warranty
CLEANING AND STORAGE
DISPOSAL / RECYCLE
CUSTOMER SERVICE
• Press the " /
continuity. The "
Apo
in the LCD.
A-HOLD
• Buzzer sounds and RED indication light
illuminates if reading is less than 25 .
• Power the unit OFF by holding the " V "
or " /
AC Voltage Measurement
Range
Resolution Accuracy
1 to 399.9
0.1V
400 to 599 1V
600 to 750 1V
Overload Protection:
Frequency:
50 to 60 Hz
Input Impedance:
Response:
Averaging
Continuity Test
Overload
Open Circuit
Protection
Voltage
600V
Appx. 0.44V
1-877-775-5346
customerservice@kleintools.com
www.kleintools.com
" button to select
" symbol will appear
" button for one second.
± (1.2% + 5 digits)
± (1.2% + 8 digits)
750V
>10M
Tone
< 25