SERVICING

Field service should be restricted to
the following:
CHECKING THE ENERGY LEVEL
OF THE BATTERY
RECHARGING THE BATTERY
CHECKING THE FUEL CELL AND
EXPIRATION DATE.
REPLACING THE FUEL CELL
CLEANING THE AIR FILTERS
CLEARING A JAM
Attempts to go beyond these procedures could
result in serious personal injury or damage to the
ST315i tool and voiding of the warranty.
There are certain problems that you may encounter
when you are using the ST315i tool that you will
be able to correct on the work site. The follow-
ing
service procedures are the only service
procedures you should attempt. Anything else
that may appear wrong with the tool should only
be diagnosed and repaired by a fully trained
service technician. If you have any reason to be-
lieve that your problem is beyond the service
procedures in this manual, contact your Sales
Representative immediately.
DANGER
Never attempt any maintenance of the ST315i
tool without rst removing the Fuel Cell, Bat-
tery and Fasteners. Maintenance should only
be started after the tool is completely inoper-
ative.
SERVICING
12

BATTERY CHECK

Periodically check on the LED Battery Voltage
Indicator Light—the LED in the Handle of the
ST315i tool. When encountering a problem, the
rst step should always be to make sure the
Battery has enough energy to operate the tool.
If the light is red, recharge the Battery. If the light
is glowing green, indicating that the Battery is
charged, check the ignition system.
FUEL CELL CHECK
Another typical service condition will occur when
the Fuel Cell becomes empty. A typical symptom
will be when the tool's Fan operates and the LED
is green, but the tool does not drive fasteners
completely.
In this case, take the Fuel Cell out
of the tool, check to see if the Fuel Cell still con-
tains
fuel and is within the expiration date.
To determine is there is any fuel left in the Fuel
Cell simply place the Metering Stem against a
solid object, and gently push about three or four
times.
A small amount of fuel should be released
each time.
Never perform this test near an open
or sparks, while smoking, or where the Fuel
may get into your eyes. If fuel is not released with
each operation of the Metering
more fuel left in the cylinder and
placed.
Dispose of the empty Fuel Cell properly.

AIR FILTER

Remove the grille from the cap and remove the
The Air Filter simply lift out.
GENTLY to remove any dust. You should check
and clean the Air Filter every two
Valve, there is no
it must be re-
days.

Publicidad

Capítulos

Tabla de contenido
loading