fAucEt INStAllAtION
StEP 2 - cONNEctING thE POWER SuPPly
Connect the connectors protruding
out of the corrugated tube to the ones
1
in the mounting box. If your model is
powered by 9V transformer, plug the
transformer into the electricity socket.
After you have connected the power
source (Battery or Transformer) wait
15 seconds in order to allow the
system to set the ideal sensor range.
As an indication that the self adjusting
2
is taking place, a LED in the sensor eye
will flash continuously. the solenoid
valve will be opened and closed for 1
second as an indication that the ideal
sensor range is set and the product is
ready for use.
Assemble the permanent panel on the
3
mounting box using the four screws
provided.
Turn on the central water supply and
4
check for leaks.
NOtE: This model includes a special aerator
that allows you to adjust the water stream
direction on site in order to prevent water
splashing if needed. To change the angle of
the water stream, simply move the adjustable
tilting plate by pressing it smoothly.
AttENtION! the aerator is tightened to
prevent removal by hand.
12
RONDA BOX
ABOuT
15
SECONDS
SEttINGS ADjuStmENt
DETECTION
RANgE
DELAY IN TIME
SECuRITY TIME
COMFORT FLuSH
Adjusting the settings with the remote control
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control,
hold the remote control straight in front of the sensor in a distance of about
6-8" (15-20cm). Choose the function you want to adjust by pressing once on
one of the function buttons. After pressing once on a specific function button, a
quick flashing of the LED at the front of the sensor will occur. At this stage, you
can change the setting by pressing the (+) or the (-) buttons, every push will
increase or decrease one level. After finishing the adjustment, turn the water
supply back on.
DELAY OuT TIME
TEMPORARY OFF
FuNCTION
SELF ADJuSTMENT
MODE
RESET
HYgIENE FLuSH
13