SEttINGS ADjuStmENt
DEtEctION RANGE:
adjusting sensor. The ideal detection range for the specific
location will be set automatically.
Only if necessary, use the remote control to adjust the sensor
range as follows:
Press the RANgE button. Wait until a quick flashing of the LED
in the sensor eye is perceived. Then, press + to increase the
range and – to reduce it. Every push will increase or decrease
one level.
Note: Once you have changed the detection range with the remote control,
the distance will be remembered by the sensor, even if the power source is
disconnected. To get back to the self adjustment mode, use the ADJ button only.
ENTRANCE TO THE SELF ADJuSTMENT MODE: Check that no
objects are in front of the sensor. Press the ADJ button. Once
a quick flashing of the LED of the sensor eye is perceived,
remove your hand holding the remote control and move away
from the sensor area. The ideal sensor range for the specific
location will be set automatically. Once the self adjustment has
taken place, the solenoid valve will be opened and closed for 1
second as an indication that the ideal sensor range was set and
the product is ready for use.
SECuRITY TIME: The Security time, prevents continuous
running of water due to reflections or vandalism. By default,
if the sensor is covered for more than 90 seconds the water
flow will shut automatically. To resume regular operation any
obstruction must be removed.
Press the SEC button. Wait until a quick flashing of the LED
in the sensor eye is perceived. Then, press + to increase the
security time and – to reduce it.
14
This faucet was supplied with a self
SEttINGS ADjuStmENt
DELAY IN TIME: It is recommended to change the delay in time
for flush valves for urinals or toilets only.
If required, the delay in time can also be modified in faucets as
follows:
Press the IN button. Wait until a quick flashing of the LED in the
sensor eye is perceived. Then, press + to increase the delay in
time and – to reduce it.
DELAY OuT TIME: This button allows modifying the water flow
time after the user removes his hands from the faucet. A delay
out time close to 0 will save more water. An increased delay
out time will make the user experience more comfortable.
If required, the delay out time can be modified as follows:
Press the OuT button. Wait until a quick flashing of the LED in
the sensor eye is perceived. Then, press + to increase the delay
out time and – to reduce it.
24 HOuR HYgIENE FLuSH: This model includes a 24 hours
hygiene flush which is disabled. To activate the hygiene flush,
press the clock button. Wait until a quick flashing of the LED in
the sensor eye is perceived. Then press + to activate the hygiene
flush. To disable it again, press – to deactivate it.
COMFORT FLuSH: If your model includes a Comfort flush
setting, it can be activated by pressing the flush button.
When the button is pressed, one blink of the LED in the sensor
eye is perceived. The pre-programmed flush cycle will take place
then.
The Comfort flush cannot be interrupted or deactivated by
pressing any button until it is over.
TEMPORARY OFF FuNCTION: This function is ideal to perform
any kind of activity in front of the sensor without operating the
system (for example, cleaning).
The faucet will remain shut for 1 minute when this button is
pressed once. To cancel this function and to return to normal
operation press the On/Off button again or wait 1 minute.
RESET BuTTON: This function restores all the factory settings
except for the sensor range. If required, press the Reset button
and without releasing it, press the + button once.
NOtE: To enter the self adjusting mode, use the ADJ button. To change the
sensor range, use the RANgE button.