In case of Motor STA360 with Inductive limit switch:
K1
+ 24 V
1
Common
- 24 V
2
START
3
STOP
4
Photocell
5
Closing with Dead
Man input
6
Open limit switch
7
Close limit switch
8
-
9
+
10
-
11
K2
Capacitor
Opening
12
Closing
13
Common
14
Neutral
Protect with a 6A differential
15
switch - overload 30 mA
Phase
16
ENGLISH
Motor terminal
board
Connect motor earth to the
control unit earth connection
8
NC Contact = Opening
s a f e t y
d e v i c e
i n
7
m o d e s : A u t o m a t i c ,
Semiautomatic with Stop
6
and Automatic with Stop.
5
Capacitor
25 μF
4
3
2
Max. 3W warning Light
1
LED fl ashing unit
Limit
Red
switch
Black
Violet (opening)
White (closing)
230 V fl ashing unit.
Caution: preflashing
not available for this
connection.
3
OPERATION
After completing the connections as indicated and checking the electrical
connections carefully, turn the power on and check that the system is functioning
correctly, as explained below.
3.1 FUNCTIONING TESTS
When all the connections have been made, it is necessary to check the
automation system.
Power up or restore the power supply and check the behaviour of this
device.
When the first Start pulse is given, the automation closes (unless the closing
limit switch is already engaged).
CAUTION - If, on the contrary, the automation opens, the motor connections
must be inverted.
3.2 TRIMMER ADJUSTMENT
Trimmer P1 - This trimmer is used to adjust the pause time before automatic closing
of the automation, when the automatic functioning mode has been selected. The
adjustment range of the pause time is between 0 and 120 seconds.
Trimmer P2 - This trimmer is used to adjust the intensity of the electronic brake,
to eliminate the inertia accumulated by the gate during movement. The trimmer
is used to adjust the brake delay, which blocks the gear motor during opening
and closing. Therefore, the braking conditions must be adapted to the weight
and the inertia of the gate.
NOTE - To keep braking stable in every season, adjust the trimmer by rotating
it counter-clockwise.
Trimmer P3 - This trimmer is used to adjust the motor torque electronically.
CAUTION - The trimmer is factory-set at the maximum value. Therefore, before
starting the automation for the first time, ensure there are no hindrances.
To reduce the torque developed by the gate driving motor, rotate the trimmer
all the way counter-clockwise.
To increase the motor torque, rotate the trimmer clockwise.
CAUTION - Adjust the trimmer correctly to exert maximum thrust on the end
of the gate leaf in accordance with the current regulations.
CAUTION - Every time the automation is started up, the device disables the
torque trimmer for the first 2 working seconds, thus enabling the motor to supply
its maximum force.
CAUTION - IF MOTORS WITH MECHANICAL CLUTCH ARE USED, in
order to limit the force of the motor follow one of these procedures:
5