DIP SWITCH SW1
S1
S2
OPERATING MODE
ON
ON
STANDARD AUTOMATIC
OFF
ON
SEMI-AUTOMATIC WITH STOP
ON
OFF
AUTOMATIC WITH STOP
OFF
OFF
DEAD MAN

4. CHECKING THE OPERATION

After selecting the operating mode and times, check the external devices
connected to the card and check the state of the LED's.
4.1 CHECKING THE OPERATION OF EXTERNAL DEVICES
Start input - N.O. type contact which supplies the start pulse to the automation.
Stop input - N.C. safety contact which has priority in all states and functions.
If the stop input is given, the device blocks the gate immediately and it only
starts up again when the start pushbutton is pressed: this closes the automation.
When the stop input is given, the device ignores all the commands.
Photocell input - N.C. safety contact which is only enabled during closing. If
the photocell is obscured, the automation stops for 1 second and the gate then
re-opens as far as the limit switch. When the gate is open and the photocells
are obscured, the photocells block gate closing.
Opening/closing safety device input - The function of this input connected
to terminal 6 depends on the operating mode. The following is a list of the
possible functions.
Opening safety device input - N.C. contact enabled in automatic and in the two
alternatives of the semiautomatic mode. This is a safety device input which is
enabled during closing and opening. When the input is enabled, the gate is
stopped immediately. When the input is disabled, the gate starts to move in the
same direction as before after a delay of 1 second. This function can be used
to protect the areas where crushing may occur.
Closing input - Input which is only enabled when Dead Man mode is selected.
ENGLISH
S3
PHOTOCELL FUNCTION
ON
IMMEDIATE RE-CLOSURE
OFF
PAUSE TIME ZERO-ING
S4
PRE-FLASHING
ON
ENABLED
OFF
DISABLED
It closes the automation when the close pushbutton is pressed and held down
(terminal 6).
Warning light output - 24VDC output with maximum load of 3W, which
commands the gate state warning light. Light OFF: gate closed. Steady light:
gate open or opening. Flashing light: gate closing.
Flashing light output - 24 V output which commands the flashing light.
This output commands the flashing light with a pulsating power supply with
frequency of 1 Hz: the light comes ON for 0.5 seconds and OFF for 0.5 sec. If
pre-flashing is enabled, this output is enabled 3 seconds before the command
to move the gate (opening and closing).
NOTE - Only use TORMATIC Series LED flashing lights or the output may
break down: this will cause the entire system to malfunction.

5. ACCESSORIES

5.1 AUTOREVERSE CARD

It is possible to fit an anti-crushing plug-in AUTOREVERSE CARD.
When an obstacle is sensed, the anti-crushing card powers the automation
down and reverses the travel if the gate is closing.

5.2 CODED KEYPAD

It is possible to install a coded keypad by connecting the decoding card to the
K3 connector.

5.3 BADGE READER

It is possible to fit a badge reader by connecting the decoding card to the K3
connector.