Type CPV...−GE−ASI−8E8A−Z−M8−CE
Load voltage connection
Rated value (protected against incorrect
polarity)
Residual ripple
Current consumption for 8 valves (at 24 V)
switching on
after current reduction (stationary)
Valves (see pneumatics manual)
Digital inputs
Design
Max. current consumption
per input
sum currents (all inputs connected)
Logic level
Reference potential
Response delay
1)
for max. 30 ms, all solenoid coils switched simultaneously
26
1)
Festo CPV...−GE−ASI−8E8A−...−CE 0703NH English
DC 21.6
26.4 V
4 Vpp
CPV10−... CPV14−...
240 mA
460 mA
95 mA
120 mA
watchdog function
active after approx.
40
100 ms
(see section 3.5)
8 digital inputs based
on IEC 1131−2 type 2
24 V DC, PNP,
status display (LED)
200 mA
200 mA
ON:
11
30 V
OFF: −30
5 V
0 V
typically 3 ms (at 24 V)