Dip-Switches - DITEC LOGICM Manual De Instalación

Tablero electrico para automacion 230 v a 1 o 2 motores
Ocultar thumbs Ver también para LOGICM:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
2.
SETTINGS
GB
2.1 Trimmer
Trimmer
TM
60 s
MIN=10 s
MAX=120 s
TR
10 s
20 s
3 s
MIN=0 s
30 s
TC
120 s
MIN=0 s
MAX=disabled
RF
R1
MAX=disabled
MIN
RP
0 s
30 s

2.2 Dip-Switches

Description
DIP1 Radio mode.
DIP2 Direction selection with OM=OFF
(1 motor mode).
DIP3 Restore automatic closing time. 50%
DIP4 Automation status at power on.
Indicates how the control panel
considers automation when powe-
red up.
DIP5 Electric lock release.
DIP6 Preflashing set at 3 s.
LOGICM - IP1854
Setting the operating time. From 10 to 120 s.
Note: with NC limit switch, set TM=MAX.
Setting motor 1 (M1) closing delay time.
When closing, motor 1 (M1) starts after a delay set with TR from 0 to 30 s relative to M2. When opening,
motor 2 (M2) starts after a delay of 3 s relative to M1.
If TR=MIN, the door wings start simultaneously.
Note: we recommend setting TR=MIN with non-overlapping door wings, and setting TR>3 s with over-
lapping door wings.
Setting automatic closing time. From 0 to 120 s.
With DIP3=OFF, once a safety switch has been activated, the counter starts as soon as the safety
switch is released (for example, after passing through the photocells), and lasts for a period of time set
with TC (50%).
With DIP3=ON, the counter starts when automation is opened and lasts for the entire duration set with
TC (100%).
Note: after the activation of the stop command, once contact 1-9 has closed again, automatic closing
is only enabled after a total, partial or step-by-step opening command.
Power setting. Sets voltage supplied to motor (1=MIN / 5=MAX).
Setting obstacle thrust. The control panel is equipped with a safety system that stops motion if an
obstacle is encountered during an opening operation and either stops or reverses motion during a
closing operation.
R1=MIN gives maximum obstacle sensitivity (minimum thrust).
R1=MAX disables detection (maximum thrust).
Setting motor 1 (M1) partial aperture. From 0 to 30 s.
Step-by-Step.
Opens towards right.
Open.
Note: with a limit switch installed, preferably
set DIP4=OFF.
Disabled.
Disabled during opening.
Enabled only with automatic closing and
with TC setting greater than 3 s.
Description
OFF
Opening.
Opens towards left.
100%
Closed.
Note: if the automatic closing function is not
used, preferably set DIP4=ON.
Enabled.
Enabled for both opening and closing.
14
ON