1.

ELECTRICAL CONNECTIONS

GB
1.1 Commands
Command
1
2
1
3
1
4
1
5
41
6
41
7
1
6
7
41
8
1
9
1
9
1
20
0
11
TM=MAX
0
11
0
12
TM=MAX
0
12
AUX
WARNING: Make a jumper on all N.C. contacts if not in use. The terminals with the same number are equal. The given operating
and performance features can only be guaranteed with the use of DITEC accessories and safety devices.
LOGICM - IP1854
Function
N.O.
AUTOMATIC CLOSING Permanently closing the contact enables automatic closing.
N.O.
OPENING
N.O.
CLOSING
N.O.
STEP-BY-STEP
N.C.
OPENING SAFETY
DEVICE
N.C.
CLOSING SAFETY
DEVICE
N.C.
SAFETY STOP
N.C.
REVERSAL SAFETY
DEVICE
N.C.
STOP
EMERGENCY STOP
N.O.
HOLD-TO-RUN
FUNCTION
PARTIAL OPENING
N.C.
M2 LIMIT SWITCH
N.O.
M2 PROXIMITY LIMIT
SWITCH
N.C.
M1 LIMIT SWITCH
N.O.
M1 PROXIMITY LIMIT
SWITCH
The opening operation starts when the contact is closed.
The closing operation starts when the contact is closed.
With D5=ON closing the contact starts a sequential opening or closing
operation: open-stop-close-open.
With D5=OFF closing the contact starts a sequential opening or closing
operation: open-stop-close-stop-open.
Note: if automatic closing is enabled, with S5=ON the stop is not perma-
nent but at a time that is set by the TC, with S5=OFF the stop is permanent.
Opening the safety contact stops the current opening operation in pro-
gress and impedes any future opening operations.
Opening the safety contact stops the current closing operation in progress
and impedes any future closing operations.
Opening the safety contact stops and prevents any movement.
Note: it does not carry out the disengagement operation. Use with photo-
cells installed only.
Opening the safety contact triggers a reversal of motion (re-opening) du-
ring a closing operation.
Opening the safety contact stops the current operation.
To enable the emergency stop function (e.g. with a specific red button),
connect the opening and closing controls to terminal 9 instead of 1 (9-3,
9-4, 9-20).
Permanently opening the safety contact enables the operator presence
dependent function.
In this state, the opening (1-3, 1-20) and closing (1-4) controls function
only if held in the pressed position and the automation stops when the
controls are released.
All safety switches, the step-by-step control and the automatic closing fun-
ction are disabled.
Closing the contact activates a partial opening operation of the door wing
powered by motor 1, of the duration set with the RP trimmer.
Once the automation stops, the partial opening control performs the oppo-
site operation to the one performed before stoppage.
The limit switch contact opening stops closing movement of motor 2
(M2).
With OM=OFF (1 motor mode) and DIP2=OFF, the limit switch stops closing
movement of motor 1 (M1).
With OM=OFF (1 motor mode) and DIP2=ON, the limit switch stops opening
movement of motor 1 (M1).
See examples given in paragraphs 5.4 and 6.4.
The limit switch contact opening stops closing movement of motor 1
(M1).
With OM=OFF (1 motor mode) and DIP2=OFF, the limit switch stops opening
movement of motor 1 (M1).
With OM=OFF (1 motor mode) and DIP2=ON, the limit switch stops closing
movement of motor 1 (M1).
See examples given in paragraphs 5.4 and 6.4.
The control panel has two spaces for coupling board, type radio receivers,
magnetic loops etc.
The coupling board working mode is selected by DIP1.
Warning: the plug-in cards must be inserted and removed with the power
supply disconnected.