4.
DOITCV16 - DOITCV22 - DOITCV33
GB
Fig.14 shows the installation measurements for a CIVIK automa-
tion made with glass door wings and fixed on glass walls.
The automation casing is supplied with SALLOX STAINLESS
STEEL S surface finish (see DITEC colour sample book code
X139).
4.1 Fastening the box
The box can be fastened to the wall as explained in chapter
3.1.
The CIVIK automation can be fastened directly onto the glass,
as shown in fig.14, using the KCVFV fastening kit and the
VP803P33 aluminium plate with SALLOX STAINLESS STEEL
S finish.
It is also possible to fasten the glass walls to the floor, as shown
in fig.14, using the KAFV fastening kit.
Warning: only stratified glass with a thickness of 10-12 mm (not
supplied by us) must be used.
The glass should be drilled at least 50 mm from its edge
4.2 Preparing the glass door wing
Use only stratified glass with a thickness of 10 mm (not supplied
by us).
To create an automation with two moving door wings, use the
KCVGCL kit for the second moving door wing.
Warning: in closing position for all-glass door wings, without
gaskets, leave at least 10 mm to avoid contact between glass
door wings.
4.3 Installing the floor guide
Fasten the guide to the floor, as shown in fig.14.
The length of the floor guide should not be greater than the
overlap between the fixed and mobile door wings, and must not
enter the passage space.
21
CIVIK - IP1953