6.
STARTING
-
Select the desired opening direction with DIP2.
-
If required, activate the closure thrust by setting DIP1=ON.
-
Set TC to the maximum.
-
Turn on the power.
Attention: the control panel performs an automatic RESET on each
start (or change of DIP2) and the first opening or closing manoeuvre
is performed at low speed allowing the automatic self-learning of
the stop positions (acquisition).
-
Check that the door is operating correctly with subsequent
opening and closing commands.
-
If required, set the automatic closing with the TC.
-
Connect possible accessories and check they are functioning.
Attention: if the RER radar is used, set the radar dip-switch RER=DX.
-
If the automation encounters an obstacle during closure, it is
detected and the automation opens again. If the automation
encounters an obstacle during opening, it is detected and the
automation stops. If the obstacle is detected twice in a row,
it is considered as the new stop until it is removed.
-
The automation is equipped with the Push&Go function. The
motorised opening or closing operation is activated when the
door is pushed.
7.
MAINTENANCE SCHEDULE (every 6 months)
Turn off the power.
-
Clean the moving parts (the carriage guides).
-
Check the belt tension.
-
Clean sensors and photocells (if present).
-
Check the stability of the automatic system and make sure
that all screws are correctly tightened.
-
Check the alignment of the door wing and the stop position.
Turn on the power.
-
Check the stability of the door and that the movement is
regular and without friction.
-
Check that all command functions are operating correctly.
-
Check that the photocells are operating correctly (if present).
-
Check that the door's developed powers are in accordance
with the present standards.