BRS-LC
NOTICE
• When changing the reamer, only use tools with a suitable width across flats.
Motor protection cap AF 21, reamer AF17.
7.6 Setting up the compressed-air motor
1
Clamping device
2
Gas nozzle
Fig. 8
Setting up the compressed-air motor
also Fig. 4 Putting into operation on page EN-11
1 Loosen the compressed-air motor from the guide block (4) by removing the screws (3).
2 Pull back the compressed-air motor (5) in its fastener.
3 Place the required distance sleeve (7) on the reamer (6).
4 Move the torch with the gas nozzle (2) to the clamping position (P2).
5 Keep the guide block (4) in the lower position (stroke down).
6 Place the compressed-air motor (5) against the gas nozzle (2) with the distance sleeve placed on top (7).
7 Fasten the adjusted motor position by means of the screws (3).
8 Move the torch out the clamping device (1) and remove the distance sleeve (7) from the reamer (6).
BAL.0030 • 2019-01-18
1
7
6
5
3
Screws
5
4
Guide block
6
7 Transport and installation
2
3
4
Compressed-air motor
7
Distance sleeve
reamer
EN - 13