7.10 Connecting the pneumatic system

For the supply, a compressed air hose with a min. inner width of
the assembly stand by means of a screw connection (not included in the delivery). A shut-off valve in the supply line is
recommended. This allows the BRS-LC to be quickly and simply depressurised in order to carry out any installation and
maintenance work.
WARNING
• The torch cleaning station BRS-LC must remain depressurised until installation has been completed.
Compressed-air motor
Nominal diameter 6
Fig. 12
Pneumatic plan
BAL.0030 • 2019-01-18
Clamping cylinder
clamp
loosen
Z2
S2
Nominal diameter 4
4
14
12
2
14
12
1
5
3
7 Transport and installation
ø
8mm is required; it is fastened to the connection plate of
Optional
back
Injector
Nominal diameter 4
1
3
a
a
b
2
Anti-spatter
agent tank
NW4
14
4
12
2
14
5
1
3
Stroke cylinder
forward
Z1
S1
b
12
6 bar
EN - 17