X8, X9, X10 - Digitala ingångar
Description
Type
USR V+ supply voltage
Input voltage
Input current
(maximum per input, USR V+ = 24 V)
Sampling interval
X12 - Analoga ingångar
Description
Type
Common mode voltage range
Input impedance
Maximum input current
Input ADC resolution
Equivalent resolution (±10 V input)
Sampling interval
X12 - Reläutgång
All models
Contact rating (resistive)
Operating time (max)
X13 - Analoga utgångar
Description
Type
Output voltage range
Output current (per output)
Output DAC resolution
Equivalent resolution
Update interval
Snabbinstallationshandbok – NextMove e100 47
Unit
V DC
Nominal
Minimum
V DC
Active
Inactive
mA
ms
Unit
V DC
mA
bits
mV
µs
Unit
ms
Unit
V DC
mA
bits
mV
ms
Value
Opto-isolated
24
12
> 12
< 2
7
1
Value
Differential
±10
120
4.9
12 (includes sign bit)
±4.9
500 (both inputs enabled)
250 (one input disabled)
All models
1 A @ 24 V DC
or
0.25 A @ 30 V AC
5
Value
Bipolar
±10
2.5
12
±4.9
1