9. EasyPort USB command interpreter
Module
Command for the
address
module
3
DAW3.0<CR>
2
DEB2.0.1<CR>
1
DE1.0.E<CR>
1
MAW1.0=201<CR>
2
MAB2.0.0=73<CR>
3
MA3.0.A=1<CR>
Examples of modify and display commands
© Festo Didactic GmbH & Co. KG „ 721876
Response from the
module
AW3.0=1234<CR>
EB2.0.1=12<CR>
E1.0.E=0<CR>
AW1.0=201<CR>
AB2.0.0=73<CR>
A3.0.A=1<CR>
Comment
Data value is
1234 hexadecimal
or 4660 decimal.
Data format for word: xxxx
Data value is 12 hexadecimal or 18
decimal.
Data format for byte: xx
Input bit 14 is read.
Data format for bit: x
Data value is
201 hexadecimal
or 513 decimal
Data value is 73 hexadecimal or
115 decimal
Output bit 10 is set to 1.