Little Giant GP-M231 Manual De Instrucciones página 2

Ocultar thumbs Ver también para GP-M231:
Tabla de contenido

Publicidad

Figure 1.
Figure 2.
Pump must be placed on a hard level surface using a leg accessory kit
available from Little Giant if unable to suspend the pump intake at least 3-1/2"
from bottom of basin.
Never place pump directly on clay, earth or gravel surfaces.
Pump can be installed with ABS, PVC, polyethylene or galvanized steel pipe.
Proper adapters are required to connect any non-metal pipe to the pump
discharge if pump is suspended by the discharge on a guide rail system.
A check valve anti-siphon valve must be used in the discharge line to prevent
back flow of liquid into the basin. The check valve should be a free flow valve
that will easily pass solids.
A gate valve should follow the check valve to allow periodic cleaning of the
check valve or removal of the pump.
The remainder of the discharge should be as short as possible with a
minimum of turns to minimize friction head loss. Do not restrict the discharge
to sizes below 1-1/4" diameter.
2
Check local electrical and building codes before installation. The
installation must be in accordance with their regulations as well as the
most recent National Electric Code (NEC).
This pump should be connected or wired to a dedicated circuit with no
other outlets or equipment in the circuit line. The circuit breaker should be
of ample capacity in the electrical circuit. See chart below:
H.P.
VOLTAGE
2
230
WINDING RESISTANCE VALUES
H.P.
SPEED
VOLTS
2
3450
230
The motor windings have a fixed resistance value and must be close
to those given in chart. To check winding resistance values, disconnect
pump cord from control panel and measure resistance at cord end. Refer
to control panel instructions for complete wiring diagram.
T1
T4
T5
MAINTENANCE
If pump does not operate properly, consult the Troubleshooting Chart. If
trouble cannot be located with the steps shown, consult your pump dealer
or take pump to a Little Giant authorized service center. The Grinder pump
is to be cleaned and sanitized prior to servicing.
CAUTION: When working on pump or switch, always disconnect pump
power cord in addition to shutting off circuit breaker before working on pump.
CLEANING CUTTER ASSEMBLY,
VOLUTE AND IMPELLER
CAUTION: When working on the pump, always disconnect power cord in
addition to shutting off circuit breaker before working on pump and always
wear eye protection.
WARNING: Do not remove motor house seal plate socket head cap
screws. The motor section of the pump is permanently lubricated with
dielectric oil and sealed at the factory. Removal of these socket head cap
screws by anyone other than an authorized service center will break the
seal and void the warranty.
WARNING: The pump should be thoroughly cleaned of all debris and
deposits before disassembling.
WARNING: This pump is equipped with a cutting mechanism that has very
sharp edges. Caution should be used when working on or near these parts.
1. Lay pump on its side on a smooth hard surface. Prior to removing
the volute, scribe a mark between the seal plate and volute.
To gain access to the rotating cutter, remove the volute by
removing the three flange hex head cap screws. Remove volute
by carefully tapping and prying the volute off the seal plate.
NOTE: Do not damage the seal plate and volute mounting surfaces.
2.
To gain access to the stationary cutter, remove the retaining ring by
removing the three flange hex head cap screws. NOTE: The stationary
cutter can be removed from the volute without having to remove the
volute.
3.
Remove the stationary cutter from the volute. If the stationary cutter is
worn, it can be turned over once to utilize the other cutter edge. If the
stationary cutter is damaged, it must be replaced.
4.
Under good light, inspect the two edges of the rotation cutter. If the
rotation cutter edges appear dull, pitted or otherwise damaged, it
should be replaced.
WIRING
CIRCUIT BREAKER AMPS
20
H.P.
BLACK TO
BLACK
PH.
WHITE
TO RED
1
1.5
3.9
Common
Black
Main
White
Auxiliary
Red
RED TO
WHITE
5.4