gas conversion

1
Injector
2
Adjustme n n t of minimum l e e vel of the flam e e
that the injector is not blocked
be carried out after gas conversion (such as soapwater or gas
detector)
After completing conversion
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7mm box spanner and
replace it with the stipulated injector for new gas supply.
Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly
tighten
Tu u rn the taps down to minimum
R R emove the knob from the tap and place a small
Control handle
bladed screwdriver in the centre of the tap shaft.
The correct adjustment is obtained when the flame
Tap
has a length of about 3 - 4 mm.
Sealing ring
For butane propane gas, the adjusting screw
must be tightly screwed in.
Refit the control knob.
M
turning
does then remove the control knob and make further
adjustments to the gas flow, testing it again once the
adjustment has been made.
Repeat this process for each one of the gas taps.
/
ake sure that the flame does not go out by quickly
from maximum flow to minimum flow. If it
back on the top place, make sure
for possible leakages must
EN-24