English
Too little gelatine/other binding agent was used
▪ "Release pressure" (page 32). Additional gelatine or other binding agents must be added
to the mixture and then it must be poured back into the bottle.
The binding agent (e.g. gelatine) was not used correctly
▪ Please follow the instructions for use for the binding agent.
► C ream charger has not been pierced
The charger used is not compatible
▪ Only use original iSi cream chargers.
The charger was inserted incorrectly
▪ Insert the charger correctly (review sequence on the right-hand page, follow step 6).
The piercing unit has been damaged
▪ Send the device to the iSi service center.
► T he content does not stay cool/warm
The stainless steel bottle gets hot or cold to the touch
The insulating chamber has been damaged – loss of thermal effect
▪ "Release pressure" (page 32). Send the device to the iSi service center.
34